Keithley 2700
Multimètre 6-1/2 digits à commutation, 2 slots (80 voies max.), 1000 V, 3 A, enregistrement, GPIB
6-1/2 digits de résolution.
Nombre d'entrées: 1 en face avant, 2 slots (80 voies max.) à l'arrière.
Mémoire tampon: 55 000 lectures.
Interfaces Ethernet et RS-232.
ExceLINX - logiciel d'enregistrement de données 1 A
Integra Series systems (2700. 2701. 2750). DC power supply products. combine precision measurement. switching. and control in a single. tightly integrated enclosure for either rack-mounted or benchtop applications. These cost-effective. high performance test platforms offer affordable alternatives to separate digital multimeters and switch systems. dataloggers/recorders. plug-in card data acquisition equipment. and VXI/PXI systems. The Integra Series plug-in switching and control modules offer unmatched flexibility and testing efficiency for a wide range of industries and applications. System builders can create test solutions with a combination of channel count. cost per channel. and system performance unmatched by any other singlebox measurement system. The input modules provide the flexibility to vary the channel count from 20 to 200 (2-pole). apply a stimulus to the device under test. route signals. control system components. and make precision measurements with up to 14 functions. Robust digital I/O capabilities can be used for triggering. handshaking with other automation equipment. and alarm limit outputs. Scan rates of up to 500 channels/second (up to 3500 readings/second on a single channel) will increase test productivity.
APPLICATIONS
Built-in measurement functions include
- DCV. ACV. DCI. ACI
- Resistance (2- or 4-wire. offset compensation selectable)
- Dry circuit ohms (20 mV clamp) 2750 only
- Temperature (with thermo-couples. RTDs. or Thermistors)
- Frequency/Period
- Continuity
SELECTOR GUIDE
Models | 3706A | 2700 | 2701 |
Digits | 7½ | 6½ | 6½ |
Expansion Channel | 576 | 80 | 80 |
DC Volts |
|
|
|
Sensitivity | 10 nV | 100 nV | 100 nV |
Maximum Reading | 300 V | 1000 V | 1000 V |
Basic Accuracy | 0.002% | 0.002% | 0.002% |
AC Volts (TRMS) |
|
|
|
Sensitivity | 100 nV | 100 nV | 100 nV |
Maximum Reading | 300 V | 750 V | 750 V |
Basic Accuracy | 0.05% | 0.06% | 0.06% |
Bandwidth | 3 Hz–300 kHz | 3 Hz–300 kHz | 3 Hz–300 kHz |
dB. dBm | - |
|
|
Frequency. Period | - | - | - |
Ohms (2/4 Wire) |
|
|
|
Sensitivity | 100 nOhm | 100 µOhm | 100 µOhm |
Maximum Reading | 100 MOhm | 120 MOhm | 120 MOhm |
Basic Accuracy | 0.004% | 0.008% | 0.008% |
Offset Compensation | - | - | - |
Dry Circuit | - |
|
|
DC Amps |
|
|
|
Sensitivity | 1 pA | 10 nA | 10 nA |
Range Span | 10 µA–3 A | 2 mA–3 A | 20 mA–3 A |
Basic Accuracy | 0.03% | 0.03% | 0.03% |
AC Amps (TRMS) |
|
|
|
Sensitivity | 1 nA | 1 µA | 1 µA |
Range Span | 1 mA–3 A | 1 A–3 A | 1 A–3 A |
Basic Accuracy | 0.08% | 0.15% | 0.16% |
Bandwith | 3 Hz–10 kHz | 3 Hz–5 kHz | 3 Hz–5 kHz |
General Features |
|
|
|
Interface | USB. GPIB. LXI/Ethernet | GPIB. RS-232 | Ethernet. RS-232 |
Reading Hold |
| - | - |
Digital I/O | 14 | 2 in/5 out (TTL) |
|
Reading Memory | 650.000 rdg | 55.000 rdg | 450.000 rdg |
Maximum Speed | >14.000 rdg/s | 2000 rdg/s | 3500 rdg/s |
Temperature Meas. | T/C. RTD. Thermistor | T/C. RTD. Thermistor | T/C. RTD. Thermistor |
Garantie Constructeur Standard | 3 Ans |
424-TRMS | Oui |
462-Courant | CA (Alternatif) | CC (Continu) |
463-Tension | CA (Alternatif) | CC (Continu) |
023-Résolution en tension | 10 µV |
034-Bande passante | 300 kHz |
037-Tension continue max. | 1000 V |
038-Tension alternative max. | 750 V |
039-Courant continu max. | 3 A |
040-Courant alternatif max. | 3 A |
382-Méthode de mesure de résistance | 2 fils | 4 fils |
119-Niveau de sécurité | CAT I |
En Stock | Non |
002-Interface RS232 | Oui |
172-GPIB | Oui |
132-Livré avec | Drivers LabVIEW, LabWindows/CVI, Visual Basic et C/C++ (type IVI) logiciel, manuel, cordons d'essai de sécurité |
035-Dimensions (HxLxP) (mm) | 89x213x370 mm |
013-Poids Net | 6.5 kg |