Fluke | 117322

Back to list

Fluke

117/322 Electrician combi kit (117/322/Tpak/TL75/C115)

Code :
FLU117322
Brand :
Fluke
Serie :
110
Manufacturer Ref. :
117322
Order Ref. :
FLUKE-117/322
Combi kit Fluke 117/322 for electrician applications.
Contain:
DMM Fluke 117.
Multimeter clamp Fluke 322.
Carrying softcase C115.
Magnetic suspension strap TPAK.
Set of test leads with hard points TL75.

3 years of warranty on Fluke 117.
2 years of warranty on Fluke 322.
1 year of warranty on accessories.
Refer to a friend
Share |
Top
Data logger on PC : No
Functions : Backlight
Bargraph
Fuse protection
Direct input for current probe : No
TRMS : Yes
Current : AC
DC
Voltage : AC
DC
Number of points (cts) : 6,000 counts
Accuracy (%) : 0.5%
Voltage resolution (V) : 0.1 mV
Minimum DC voltage (V) : nc
Minimum AC voltage (V) : nc
Maximum DC voltage (V) : 600V DC
Maximum AC voltage (V) : 600V AC
Minimum DC current (A) : nc
Minimum AC current (A) : nc
Maximum DC current (A) : 10A DC
Maximum AC current (A) : 400A AC
Measures (Type) : Resistance
Capacitance
Frequency
Continuity test
Diode test
Min/Max
Multimeter bandwidth (Hz) : 50 kHz
Autonomy (Hour) : 400 hour
Safety Level : CAT I
CAT II
CAT III
Safety Overvoltage : CAT III 600V
Communication interface (Type) : na
Additional Characteristics : Voltage detection without contact
Warranty:
3 years on Fluke 117.
2 years on Fluke 322.
1 year on accessories.
Package includes : DMM Fluke 117, multimeter clamp Fluke 322, carrying softcase C115, magnetic suspension strap TPAK, set of test leads with hard points TL75, manual.
Dimension (HxWxD) (mm) : Multimeter: 167x84x46 mm.
Clamp: 190x63x35 mm.
Net Weight (kg) : 1.56 kg
Standard Manufacturer Warranty (Year) : 3 YEARS
Top

Fluke  117

 

 

For electricians working in commercial and noncommercial premises (like hospitals and schools), the 117 is recommended. It includes extras like non-contact voltage detection to help get the job done faster and safer.

Specifications
Maximum voltage between any terminal and earth ground

600 V
Surge protection

6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input

11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital: 6,000 counts, updates 4 per second
Bar graph

33 segments, updates 32 per second
Operating Temperature

-10 °C to + 50 °C
Storage Temperature

-40 °C to + 60 °C
Battery type

9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life

400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 1.5 % + 2
Diode Test
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 μF / 0.01 μF
Range/Resolution: 100.0 μF / 0.1 μF
Range/Resolution: 9999 μF / 1 μF
Range/Resolution: 100 μF to 1000 μF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 μF
Accuracy: 5% + 20%
LoZ capacitance
Range: 1 nF to 500 μF
Accuracy: 10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution: -40 °C to 400 °C / 0.1 °C
Accuracy: 1% + 102
Range/Resolution: -40 °F to 752 °C / 0.2 °F
Accuracy: 1% + 182
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3

20 A continuous overload for 30 seconds max
DC amps
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3

20 A continuous overload for 30 seconds max
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2

Notes:
1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is specified from 0.0V.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.

Mechanical & General Specifications
Size
Height: 16.7 cm (6.57")
Length: 8.4 cm (3.31")
Width: 4.62 cm (1.82")
Weight

392 g (0.866 lbs)
Warranty

3 years



Fluke 322 Clamp Meter


 

Big features, small package

The Fluke  322 is designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meter is ideally suited for current measurements up to 400 A in tight cable compartments. The Fluke 322 also offers DC voltage measurements and has a higher resolution for loads below 40 A.


These affordable instrument combine a compact package with a strong feature set:
  • New smaller size fits easily into tight places
  • Precise measurements with 1.8% basic accuracy
  • Resolution up to 0.01A and 0.1 V
  • Measures AC current to 400 A
  • Measures AC volts to 600 V
  • Measures DC volts to 600 V
  • Resistance measurement to 400 Ω
  • Continuity for quick checking of shorts
  • Automatic low battery indicator
  • Display hold function
  • Two year warranty

Specifications
Voltage DC
Range: 0 - 400 V (Fluke 322 only)
Resolution: 0.1 V
Range: 0 - 600 V (Fluke 322 only)
Resolution: 1 V
Accuracy: 1% ± 5 counts
Voltage AC
Range: 0 - 400 V
Resolution: 0.1 V
Range: 0 - 600 V
Resolution: 1 V
Accuracy: 1.2% ± 5 counts (50 - 400 Hz)
AC Response: Averaging
Current AC
Range: 0 - 400 A
Resolution: 0.1 A
Range: 0 - 40 A (Fluke 322 only)
Resolution: 0.01 A
Accuracy: 1.8% ± 5 counts (50 - 60 Hz)
Accuracy: 3.0% ± 5 counts (60 - 400 Hz)
AC Response: Averaging
Resistance
Range: 0 - 400 Ω
Resolution: 0.1 Ω
Accuracy: 1% ± 5 counts
Continuity

<= 30 Ω

Environmental Specifications
Operating Temperature

-10°C to +50°C
Storage Temperature

-30 ºC to +60 ºC
Operating Altitude

2,000 meters
Temperature De-rating

Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC

Safety Specifications
Safety Rating

IEC 1010-2-032, 600V CAT III

Mechanical & General Specifications
Size

190 x 63 x 35 mm
Weight

230 g
Warranty

Two years
Battery Life

100 hours typical (2 AAA carbon zinc)
Jaw Opening

25 mm