Fluke | 116

Back to list

Fluke

TRMS Handheld digital multimeter; 6,000 counts; 0.5% accuracy

Code :
FLU116
Brand :
Fluke
Serie :
110
Manufacturer Ref. :
116
Order Ref. :
Fluke-116
multimètre avec mesure de température et de micro-ampères.
For heating, ventilation and air conditioning (HVAC) systems.
* True RMS measurements
* 0.5% basic accuracy
* 6,000 counts resolution
* Built-in thermometer for HVAC applications
* Microamps to test flame sensors
* Low input impedance: helps prevent false readings due to ghost voltage
* Large white LED backlight to work in poorly lit areas
* Resistance, continuity, frequency and capacitance
* Min/Max/Average with elapsed time to record signal fluctuations
* Compact ergonomic design for one-handed operation
* Compatible with optional magnetic hanger (ToolPak™)
* CAT III 600 V safety rated
Refer to a friend
Share |

219,00

Add to cartOrder/Quotation
Demande de devis
  • J’ajoute mes produits à mon panier
  • J'accède à mon panier
  • Je demande mon devis à l'étape n°4
Express Quote for this product
Top
Data logger on PC : No
Functions : Large display
Backlight
Bargraph
Direct input for current probe : No
TRMS : Yes
Current : AC
DC
Voltage : AC
DC
Number of points (cts) : 6,000 counts
Accuracy (%) : 0.5%
Voltage resolution (V) : 0.1 mV
Minimum DC voltage (V) : nc
Minimum AC voltage (V) : nc
Maximum DC voltage (V) : 600V DC
Maximum AC voltage (V) : 600V AC
Minimum DC current (A) : nc
Minimum AC current (A) : nc
Maximum DC current (A) : 600 uA DC
Maximum AC current (A) : 600 uA AC
Measures (Type) : Resistance
Capacitance
Frequency
Temperature
Continuity test
Diode test
Min/Max
Multimeter bandwidth (Hz) : 50 kHz
Autonomy (Hour) : 400 hour
ATEX : No
Safety Level : CAT I
CAT II
CAT III
Safety Overvoltage : CAT III 600V
Communication interface (Type) : na
Additional Characteristics : -
Package includes : TL75 Test leads, 80BK Integrated Temperature probe, holster, installed 9 V battery, user manual
Dimension (HxWxD) (mm) : 167x84x46 mm
Net Weight (kg) : 550 g
Standard Manufacturer Warranty (Year) : 3 YEARS
Top

Model 116

 

 

The 116 is for heating, ventilation and air conditioning (HVAC) engineers. It includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.

Specifications
Maximum voltage between any terminal and earth ground

600 V
Surge protection

6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph

33 segments, updates 32 per second
Operating Temperature

-10 °C to + 50 °C
Storage Temperature

-40 °C to + 60 °C
Battery type

9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life

400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 1.5 % + 2
Diode Test
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 μF / 0.01 μF
Range/Resolution: 100.0 μF / 0.1 μF
Range/Resolution: 9999 μF / 1 μF
Range/Resolution: 100 μF to 1000 μF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 μF
Accuracy: 5% + 20%
LoZ capacitance
Range: 1 nF to 500 μF
Accuracy: 10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution: -40 °C to 400 °C / 0.1 °C
Accuracy: 1% + 102
Range/Resolution: -40 °F to 752 °C / 0.2 °F
Accuracy: 1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution: 600.0 μA / 0.1 μA
Accuracy: 1.0% + 2
DC μamps
Range/Resolution: 600.0 μA / 0.1 μA
Accuracy: 1.0% + 2
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2

Notes:
1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is specified from 0.0V.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.

2) Frequency is ac coupled, 5Hz to 50 kHz for ac voltage

Mechanical & General Specifications
Size
Height: 16.7 cm (6.57")
Length: 8.4 cm (3.31")
Width: 4.62 cm (1.82")
Weight

392 g (0.866 lbs)
Warranty

3 years

Top

Brochures