Amprobe | 30XR-A

Back to list

Amprobe

Handheld digital multimeter, 2,000 counts, 600V AC/DC, 10A AC/DC

Code :
AMP30XR-A
Brand :
Amprobe
Serie :
30XR-A
Manufacturer Ref. :
30XR-A
Order Ref. :
30XR-A
Digital Multimeter.
Voltage: 600V AC/DC.
Current: 10A AC/DC.
Non-contact voltage detector.
Resistance, diode test, conitnuity.
Min/Max, Data Hold.
Auto power off to save battery life
Separate door for easy battery and fuse access.
Magne-Grip™ Holster with magnetic hanging strap.
Three-year warranty.
Refer to a friend
Share |
Promotion

82,00 €

69,00

Add to cartOrder/Quotation
Demande de devis
  • J’ajoute mes produits à mon panier
  • J'accède à mon panier
  • Je demande mon devis à l'étape n°4
Express Quote for this product
Top
Data logger on PC : No
Functions : Fuse protection
Direct input for current probe : No
Promotion : Yes
TRMS : No
Current : AC
DC
Voltage : AC
DC
Number of points (cts) : 1,999 counts
Accuracy (%) : 1.5%
Voltage resolution (V) : 100uV
Minimum DC voltage (V) : 200mV DC
Minimum AC voltage (V) : 200mV AC
Maximum DC voltage (V) : 600V DC
Maximum AC voltage (V) : 600V AC
Minimum DC current (A) : 200uA DC
Minimum AC current (A) : 200uA AC
Maximum DC current (A) : 10A DC
Maximum AC current (A) : 10A AC
Measures (Type) : Resistance
Continuity test
Diode test
Min/Max
Multimeter bandwidth (Hz) : 500Hz
Autonomy (Hour) : 200 hour
ATEX : No
Safety Level : CAT I
CAT II
CAT III
Safety Overvoltage : CAT II 600V / CAT III 300V
Communication interface (Type) : na
Additional Characteristics : Non contact voltage detection
Package includes : Test leads,
9 V battery (installed), Magne-Grip™ Holster with
magnetic hanging strap, users manual
Dimension (HxWxD) (mm) : 196x92x60 mm
Net Weight (kg) : 426 g (1 lb)
Standard Manufacturer Warranty (Year) : 3 YEARS
Top
30XR-A
Manual Ranging Digital Multimeter

  • Non-contact voltage detector
  • Separate door for easy battery and fuse access
  • Manual Ranging; Display: 3-1/2 digit LCD, 1999 counts
  • Display Update Rate: 2.5/sec, nominal
  • Power Battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
  • Operating Temperature: 0 °C to 45 °C at < 70 % R.H.
  • Storage Temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
  • Low battery indication
  • Overrange indication
  • Min/Max and Data Hold

 

Specifications


DC Voltage Ranges:     200 mV, 2 V, 20 V, 200 V, 600 V
DC Voltage Accuracy:     all ranges: ± (1 % rdg + 1 dgt)
DC Voltage Resolution:     100 μV
DC Voltage Input Impedance:     10 MΩ
AC Voltage (45 Hz to 500 Hz) Ranges:     200 mV, 2 V, 20 V, 200 V, 600 V
AC Voltage (45 Hz to 500 Hz) Accuracy:     all ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) Resolution:     100 μV
AC Voltage (45 Hz to 500 Hz) Input Impedance:     10 MΩ
DC Current Ranges:     200 μA, 2 mA, 20 mA, 200 mA, 10 A
DC Current Accuracy:     200 μA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)
DC Current Accuracy:     10 A range: ± (2.0 % rdg + 3 dgts)
DC Current Resolution:     0.1 μA
DC Current Voltage Burden (Max):     200 μA range: 1 mV/μA
DC Current Voltage Burden (Max):     2 mA range: 100 mV/1mA
DC Current Voltage Burden (Max):     20 mA range: 13 mV/1 mA
DC Current Voltage Burden (Max):     200 mA range: 4.6 mV/1 mA
DC Current Voltage Burden (Max):     10A range: 40 mV/1 A
AC Current (45 Hz to 500 Hz) Ranges:     200 μA, 2 mA, 20 mA, 200 mA, 10 A
AC Current (45 Hz to 500 Hz) Accuracy:     200 μA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)
AC Current (45 Hz to 500 Hz) Accuracy:     10A range: ± (2.5 % rdg + 4 dgts)
AC Current Resolution:     0.1 μA
AC Current Voltage Burden:     See DC Current
Non-Contact Voltage Detector (NCV) AC Volts:     70 to 600 V ac
Non-Contact Voltage Detector (NCV):     Red LED and Audible Indicator