<< Volver

|
 |
Prix Testoon : 449 € Sin tasas Cantidad :


Marca : Fluke
Ref. fabricante : 337
Presentación

The top-of the-line True-rms clamp meter, large jaw measures ac/dc current and voltage, ohm, motor start-up current (in-rush), frequency, MIN/MAX capability and a large backlit display.
Three year warranty
<< Productos de la misma categoría

Cargar a distancia la documentación
|
| |
 |
| Jaw opening : | nc
| | Current : | AC DC
| | Voltage : | AC DC
| | Número de puntos (pts) : | nc
| | Voltaje de C.C. mínimo (v) : | 0V DC
| | Voltaje ca Mínimo (v) : | 0V AC
| | Voltaje de C.C. máximo (v) : | 600V DC
| | Voltaje ca Máximo (v) : | 600V AC
| | Corriente de la C.C. del mínimo (a) : | 0A DC
| | Corriente de la CA del mínimo (a) : | 0A AC
| | Corriente de la C.C. del máximo (a) : | 1000A DC
| | Corriente de la CA del máximo (a) : | 1000A AC
| | Funciones (tipo) : | Resistance Frequency Continuity test Diode test Min/Max
| | Anchura de banda del multímetro (hertzios) : | nc
| | Autonomía (hora) : | 150 horas
| | Nivel de seguridad : | CAT I CAT II CAT III
| | Sobretensión de seguridad : | CAT III 600 V
| | Características adicionales : | -
| | Dimensionar (HxWxD) (milímetros) : | 40x250x80 mm
| | Peso neto (kilogramo) : | 310 g
| | Garantía estándar del fabricante (año) : | 3 años | |
|
| |
 |
Marca : Fluke Serie : serie 330 Ref. fabricante : 337 Ref. pedido : Fluke 337A Peso : 0.51 kg
Clamp meter Fluke 337
|
Specifications |
|
Voltage DC |
Range: |
0 - 600.0 V |
|
|
Accuracy : |
1% ± 5 counts |
|
|
Voltage AC |
Range: |
0 - 600.0 V |
|
Accuracy: |
1% ± 5 counts (20-100 Hz), 6% ± 5 counts (100-400 Hz) |
|
AC Response: |
True-rms |
|
|
Current DC |
Range: |
0 - 999.9 A |
|
|
Accuracy: |
2% ± 3 counts |
|
|
Current AC |
Range: |
0 - 999.9 A |
|
Accuracy: |
2% ± 5 counts (10-100 Hz), 6% ± 5 counts (100 - 400 Hz) |
|
Crest Factor(50/60 Hz): |
3 @ 500A, 2.5 @ 600A, 1.42@1000 A, add 2% for CF>2 |
|
AC Response: |
True-rms |
|
|
Resistance |
Range: |
0 - 600.0 Ω, 6001 - 6000 Ω |
|
|
Accuracy: |
1.5% ± 5 counts |
|
|
Frequency |
Range: |
5 - 400Hz |
|
|
Accuracy: |
0.5% ± 5 counts |
|
Trigger Level: |
10-100 Hz >= 5A, 5-10 Hz, 100-400 Hz >=10A |
|
|
Inrush Current |
Integration Time: |
100 ms |
|
|
|
Continuity |
|
<= 30 Ω |
|
|
|
MIN/MAX |
|
Yes |
|
|
|
Environmental Specifications |
|
Operating Temperature |
|
-10 °C to +50 °C, -14 °F to 122 °F |
|
|
|
Storage Temperature |
|
-40ºC to +60ºC, -22 °F to 140 °F |
|
|
|
Operating Altitude |
|
2,500 meters max, 6,500 ft max |
|
|
|
Temperature De-rating |
|
Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC (above 82.4°F or below 64.4°F) |
|
|
Safety Specifications |
|
Safety Rating |
|
IEC 1010-2-032, 600V CAT III |
|
|
|
Mechanical & General Specifications |
|
Size |
|
250mm x 80mm x 40mm (9.875" x 3.125" x 1.625") |
|
|
Weight |
|
310 g (11oz) |
|
|
|
Warranty |
|
Three years |
|
|
|
Battery Life |
|
Alkaline approximately 150 hours continuous |
|
|
Automatic low battery indicator |
|
|
Backlight |
|
Yes |
|
|
|
Display Hold |
|
Yes |
|
|
|