Testoon Price : 480 € Exc VAT
Quantity :


Brand : Fluke
Manufacturer Ref. : 771
Presentation

Milliamp process clamp meter to measuring mA loop signals.
Measuring and troubleshooting 4-20 mA signals: -20.99 to +20.99mA.
Measuring and troubleshooting 10-50 mA signals: -21 to -99.9mA; +21 to +99.9mA.
Resolution: 0.1mA.
Zero, Hold, backlight.
Measurement spotlight.
Similar products
|
| |
 |
| Jaw opening : | Max. diameter conductor: 4.5mm.
| | Autonomy (Hour) : | 20 hours
| | Additional Characteristics : | Measuring and troubleshooting 4-20mA & 10-50mA
| | Package includes : | Carrying softcase, user manual
| | Dimension (HxWxD) (mm) : | 212x59x38 mm
| | Net Weight (kg) : | 260 g
| | Standard Manufacturer Warranty (Year) : | 1 YEAR | |
|
| |
 |
Brand : Fluke Manufacturer Ref. : 771 Order Ref. : Fluke-771
Fluke 771 Milliamp Process Clamp Meter
Don’t break the loop on 4-20 mA signal measurements
Measure 4-20 mA signals without
breaking the loop with this new, compact clamp meter for PLC and
control systems analog I/O. The detachable clamp with extension cable
allows you to take measurements in tight locations, and the built-in
spot light illuminates hard to see wires in dark enclosures. Use the 771 to:
- Measure mA signal for PLC and control system analog I/O
- Measure 4 to 20 mA output signals from transmitters without breaking the loop.
- Count on best in class accuracy of 0.2%
- Measure mA signals with 0.01 mA resolution
|
Features at a glance
- Measure mA signals for PLC and control system analog I/O
- Measure 4 to 20 mA output signals from transmitters without breaking the loop
- Best in class 0.2 % accuracy
- Resolution and sensitivity to 0.01 mA
- Hold function captures and displays changing measurements
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatic power off after 15 minutes and 2 minute automatic off for backlight and spotlight
|
|
| Environmental Specifications |
| Diameter of measurable conductor |
|
| Operating temperature |
|
| Storage Temperature |
|
| Operating Humidity |
|
< 95% @ <30 ºC, < 75% @ 30 to 55ºC |
|
| Operating Altitude |
|
| IP Rating |
|
| Size |
|
59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.) |
|
| Weight |
|
| Vibration |
|
| Shock |
|
1 meter drop test (except the jaw) |
|
| EMI/RFI |
|
| Temperature Coefficient |
|
| Power, battery life |
|
(2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical |
|
| Warranty |
|
Three years for electronics, 1 year for clamp cable assembly |
|
|
|