 | | SIMPLIFIBER PRO VERIFICATION TESTING |  |
|
 | 
<< Return

|
 |
Testoon Price : 1 995 € Exc VAT Quantity :


Brand : Fluke Networks
Manufacturer Ref. : FTK1000
Presentation

Multimode Optical fiber basic kit.
Include:
1 optical power meter SimpliFiberPro.
1 multimode 850/1300 nm source.
1 soft case, 1 user manual.
<< Similar products
|
| |
 |
| Type : | optical wattmeter Optical source
| | Calibrated wavelengths (Powermeter)(nm) : | 850 nm 1300 nm 1310 nm 1490 nm 1550 nm 1625 nm
| | Calibrated wavelengths (Source) (nm) : | 850 nm 1300 nm
| | Min input power (Powermeter)(dBm) : | -60 dBm (1300/1310/1490/1550/1625 nm); -52 dBm (850 nm)
| | Max input power (Powermeter)(dBm) : | +10 dBm
| | Output power (Source)(dBm) : | -20 dBm (MM); 8 dBm minimum, -7 dBm nominal (SM)
| | Accuracy (dBm) : | +-0.25 dB
| | Detector type : | InGaAs
| | Autonomy (Hour) : | 50 hours (powermeter); 40 hours (Source)
| | Additional Characteristics : | -
| | Package includes : | SimpliFiber Pro optical power meter, SimpliFiber Pro 850/1300 multimode source, USB cable for PC communications, 4 AA alkaline batteries, Carrying case, Getting-started guide and instruction sheets, SimpliFiber Pro product manuals CD, LinkWare CD
| | Dimension (HxWxD) (mm) : | SimpliFiber Pro: 165x80x39 mm
Source: 142x81x41 mm
| | Net Weight (kg) : | SimpliFiber Pro: 325 g; Source: 278 g
| | Standard Manufacturer Warranty (Year) : | 1 YEAR | |
|
| |
 |
Brand : Fluke Networks Serie : Simplifiber Pro Manufacturer Ref. : FTK1000 Order Ref. : FTK1000
SimpliFiber® Pro Optical Power Meter and Fiber Test Kits |
| Simple-to-use
fiber-loss tester with advanced time-saving features. Choose from
various kits with configurations to meet your fiber verification,
inspection, and cleaning needs. |
|
|
- Single-port, simultaneous dual-wavelength feature completes testing
in half the time and saves measurements from both wavelengths into one
record
- Additional 1490 and 1625 nm wavelengths extends product use to broader applications
- CheckActive™ feature emits an audible tone and displays an icon
when a live fiber is detected, eliminating the need to set up a
measurement
- FindFiber™ Remote ID enables one individual to quickly identify
cable connections or routings (especially useful at patch panels),
eliminating the need for multiple technicians on opposite ends of a
fiber link to match color combinations
- Min/Max capability automates precision tracking of intermittent power fluctuations
- Large internal memory save 1000 results which enables continuous testing and recording
- LinkWare Cable Test Management software helps to analyze test results and create professional test reports
- Various kit configurations for all “first line” fiber handling
needs, including fiber verification, inspection, and cleaning – all
housed in a professional, rugged carrying case
Today’s high-bandwidth premises networks depend on a reliable fiber
optic infrastructure. Proper installation and maintenance of fiber
cabling is imperative for minimizing network downtime. Whether you
require basic fiber verification capabilities, advanced troubleshooting
and inspection, or documented loss and power measurements, Fluke
Networks’ SimpliFiber® Pro Optical Power Meter and Fiber Test Kits are
the best first-line fiber instruments to meet your needs.
SimpliFiber® Pro Optical Power Meter and Fiber Test Kits include all
the tools necessary to verify and troubleshoot optical fiber cabling
systems, measure loss and power levels, and inspect and clean connector
end-faces. Replacing the popular SimpliFiber series, these next
generation optical loss test kits boast industry-leading functions such
as dual-wavelength testing and automatic-wavelength detection, in
addition to unique features such as CheckActive™, FindFiber™, and
Min/Max. With such advanced, yet easy-to-use, capabilities that reduce
test times, SimpliFiber Pro is simply the best first-line fiber test
kit on the market.
| Specifications |
 |
| Environmental Specifications |
| Operating Temperature |
-10º C to 50º C |
| Storage Temperature |
-20º C to 50º C |
| Operating Humidity |
- 95% (10º C to 35º C) Non-Condensing
- 75% (35º C to 40º C) Non-Condensing
- Uncontrolled <10º C
|
| EMI, RFI, EMC |
Standards compliant1 |
1 Conforms to
relevant European Union directives; Conforms to relevant Australian
standards; Listed by the Canadian Standards Association; Complies with
21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)
| Optical Power Meter |
| Detector Type |
InGaAs |
| Calibrated Wavelengths |
850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm |
| Measurement Range |
- +10 to -52 dBm (850 nm)
- +10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)
|
| Power Measurement Linearity |
- ±0.2 dB (850 nm)1
- ±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)2
|
| Power Measurement Uncertainty3 |
±0.25 dB |
| Display Resolution, dB or dBm |
0.01 dB |
| Auto Dual-Wavelength Switching |
Yes |
| Power Display Units |
dBm, mW, μW |
| Auto-Wavelength Detection |
Yes |
| Data Storage |
1000 records, multiple wavelengths per record |
| External Interface |
USB, 2.0 full speed |
| Optical Connector |
Removable adapter, SC adapter as default, optional adapters include LC, ST |
| Display update rate |
1 reading per second |
| Reference |
Individually set for each wavelength |
| FindFiber ID detection |
Yes |
| Power Requirement |
2 AA Alkaline batteries |
| Battery Life4 |
> 50 Hours (typical) |
| Automatic Power Off |
10, 20, 30 or 60 minutes (can be disabled by user) |
| Low Battery Warning |
Yes, low battery icon blinks |
| Size (L x W x H) |
6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm) |
| Weight |
11.5 oz (325 grams) |
1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm 2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm 323°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi
mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB
for 1625 nm, 4 For measured power levels 0 dBm or less,
battery life depends on the condition and type of batteries used. Fluke
Networks recommends alkaline batteries.
| Multimode Optical Source |
| Emitter Type |
LED |
| Central Wavelength |
850 nm, 1300 nm |
| Wavelength Accuracy |
- 850 nm: +30/- 10 nm
- 1300 nm: +/- 20 nm
|
| Spectral Width (FWHM) |
- 850 nm: 50 nm (typical)
- 1300 nm: 135 nm (typical)
|
| Minimum Output Power |
850/1300 nm: ³ -20 dBm |
| Power Output Stability1 |
±0.1 dB over 8 hours |
| Auto Dual-Wavelength Switching |
Yes. Can be enabled/disabled by user. |
| Optical Output Connector |
Fixed SC |
| FindFiber Code Generation |
Yes. Fixed at ID 1. |
| Modes |
CW, 2 kHz modulated, Auto-wavelength |
| Power Requirement |
2 AA Alkaline batteries. |
| Battery Life2 |
40 hrs (typical) |
| Automatic Power Off |
30 minutes (can be disabled by user) |
| Low Battery Warning |
Yes, LED blinks |
| Size (L x W x H) |
5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
| Weight |
1.8 oz (278 g) |
1 23° C ± 2° C, after 5 minutes warm-up time 2In auto-wavelength mode, battery life depends on the condition and type
of batteries used. Fluke Networks recommends alkaline batteries.
| Singlemode Optical Source |
| Emitter Type |
FP Laser: dual 1310 nm/1550 nm |
| Central Wavelength |
1310 nm, 1550 nm |
| Wavelength Accuracy |
- 1310 nm: +/- 20 nm
- 1550 nm: +/- 30 nm
|
| Spectral Bandwidth (RMS) |
- 1310 nm: 2 nm (maximum)
- 1550 nm: 3 nm (maximum)
|
| Minimum Output Power |
1310/1550 nm: ³ -7 dBm (typical) |
| Power Output Stability1 |
±0.25 dB over 8 hours |
| Auto Dual-Wavelength Switching |
Yes. Can be enabled or disabled by user. |
| Optical Connector |
Fixed SC |
| Launch Condition |
9/125 μm fiber |
| FindFiber Code Generation |
Yes. Fixed at ID 2. |
| Modes |
CW, 2 kHz modulated, Auto-wavelength |
| Power Requirement |
2 AA Alkaline batteries |
| Battery Life2 |
30 hrs (typical) |
| Automatic Power Off |
30 minutes (can be enabled or disabled by user) |
| Low Battery Warning |
LED blinks. |
| Size (L x W x H) |
5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
| Weight |
9.8 oz (278 grams) |
1 23° C ± 2° C, after 5 minutes warm-up time 2In auto-wavelength mode, battery life depends on the condition and type
of batteries used. Fluke Networks recommends alkaline batteries.
| FindFiber Source Specifications |
| Emitter Type |
Laser |
| Source Connector |
Fixed SC |
| FindFiber Code Generation |
1 through 8. Default is 3. |
| Power On/Low-battery Indicator |
LED |
| Power Requirement |
2 AA Alkaline batteries |
| Battery Life |
> 80 Hours (typical) |
| Automatic Power Off |
30 minutes |
| Low Battery Warning |
LED blinks |
| Size (L x W x H) |
7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm) |
| Weight |
4.4 oz (125 g) |
| Safety |
Meets Class 1 CDRH |
|
Kits
| Model Number/Name |
Description |
| FTK1450 |
Complete
Fiber Verification Kit with FT500 FiberInspector Mini – Includes
SimpliFiber Pro optical power meter, 850/1300 multimode source,
1310/1550 singlemode source, VisiFault VFL, FT500 FiberInspector Mini,
two (2) FindFiber Remote ID sources, and carrying case; ST and LC
adapter, NFC-KIT-BOX fiber optic cleaning kit |
| FTK1350 |
Multimode
Fiber Verification Kit with FT500 FiberInspector Mini – Includes
SimpliFiber Pro optical power meter, 850/1300 multimode source,
VisiFault VFL, FT500 FiberInspector Mini, FindFiber Remote ID source,
and carrying case; ST and LC adapter |
| FTK1300 |
Multimode
Fiber Verification Kit with FT120 FiberViewer – Includes SimpliFiber
Pro optical power meter, 850/1300 multimode source, VisiFault VFL,
FT120 FiberViewer, FindFiber Remote ID source, and carrying case; ST
and LC adapter |
| FTK1000 |
Multimode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, and carrying case |
| FTK2000 |
Singlemode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, 1310/1550 singlemode source, and carrying case |
|
|  |
 |  |  |
|