Kit basique de vérification fibre multimode Simplifiber Pro SIMPLIFIBER PRO VERIFICATION TESTING SIMPLIFIBER PRO VERIFICATION TESTING

French   German   Spanish    Who are we ?  | Contact us  | My Account  | Cart (0 Article)
 

On-line sale of test and measurement equipments

CONTACT
+33 1 71 16 17 00

  Select a Domain :

  > AIR - GAS
  > BOOKS
  > CALIBRATOR
  > CASES AND HOLSTERS
  > CHEMICAL MEASUREMENTS
  > COMPONENTS & CARD TEST
  > CONNECTORS AND ADAPTERS
  > DATA ACQUISITION/ANALYSIS
  > DIMENSION-DISTANCE
  > ELECTRICAL SAFETY TEST
  > GRAPHICAL RECORDERS
  > INDIVIDUAL PROTECTION EQUIPMENTS (EPI)
  > INFILTROMETRY
  > INSPECTION TESTER
  > LIGHT
  > MULTIMETER / CLAMP
  > OPTICAL / FIBER OPTICS
 - OTDR Fiber optic test set
 - Optical Network Analyser
 - Optical fiber inspection microscope
 - Optical power meters and sources
  > OSCILLOSCOPE
  > POWER / ENERGY / PERTURBATION
  > POWER SUPPLY
  > PRESSURE
  > PROBES, TEST LEADS AND CABLES
  > RF AND MICROWAVE
  > RADIOCOMMUNICATION
  > SIGNAL GENERATOR
  > SOUND AND VIBRATION
  > SPEED
  > TEACHING AIDS
  > TELECOM / DATACOM
  > TELEVISION / VIDEO TEST
  > TEMPERATURE / HUMIDITY
  > THERMOGRAPHIC CAMERAS
  > VARIOUS ACCESSORIES
  > WEIGHING INSTRUMENTS/DYNAMOMETERS


Help

     Tips & Tricks to use Testoon

Catalogue

     Metrel

Company Profile

     Anritsu Corporation
     Ideal Industries
     Metrel
     Trend Communications
SIMPLIFIBER PRO VERIFICATION TESTING

<< Return


SIMPLIFIBER PRO VERIFICATION TESTING

Testoon Price : 1 995 € Exc VAT

Quantity :
 

  Add to my basket


  Get an Express Quote by email


  Tell a friend

Brand : Fluke Networks
Manufacturer Ref. : FTK1000

Presentation

Multimode Optical fiber basic kit.
Include:
1 optical power meter SimpliFiberPro.
1 multimode 850/1300 nm source.
1 soft case, 1 user manual.

<< Similar products

Top Characteristics Product Details

Type :optical wattmeter
Optical source
Calibrated wavelengths (Powermeter)(nm) :850 nm
1300 nm
1310 nm
1490 nm
1550 nm
1625 nm
Calibrated wavelengths (Source) (nm) :850 nm
1300 nm
Min input power (Powermeter)(dBm) :-60 dBm (1300/1310/1490/1550/1625 nm); -52 dBm (850 nm)
Max input power (Powermeter)(dBm) :+10 dBm
Output power (Source)(dBm) :-20 dBm (MM); 8 dBm minimum, -7 dBm nominal (SM)
Accuracy (dBm) :+-0.25 dB
Detector type :InGaAs
Autonomy (Hour) :50 hours (powermeter); 40 hours (Source)
Additional Characteristics :-
Package includes :SimpliFiber Pro optical power meter, SimpliFiber Pro 850/1300 multimode source, USB cable for PC communications, 4 AA alkaline batteries, Carrying case, Getting-started guide and instruction sheets, SimpliFiber Pro product manuals CD, LinkWare CD
Dimension (HxWxD) (mm) :SimpliFiber Pro: 165x80x39 mm
Source: 142x81x41 mm
Net Weight (kg) :SimpliFiber Pro: 325 g; Source: 278 g
Standard Manufacturer Warranty (Year) :1 YEAR

Top Characteristics Product Details

Code : FLNFTK1000
Brand : Fluke Networks
Serie : Simplifiber Pro
Manufacturer Ref. : FTK1000
Order Ref. : FTK1000


SimpliFiber® Pro Optical Power Meter and Fiber Test Kits

Simple-to-use fiber-loss tester with advanced time-saving features. Choose from various kits with configurations to meet your fiber verification, inspection, and cleaning needs.
SimpliFiber Pro Optical Power Meter and Fiber Test Kits
SimpliFiber Pro Optical Power Meter and Fiber Test Kits SimpliFiber Pro Optical Power Meter and Fiber Test Kits SimpliFiber Pro Optical Power Meter and Fiber Test Kits SimpliFiber Pro Optical Power Meter and Fiber Test Kits


At a Glance
  • Single-port, simultaneous dual-wavelength feature completes testing in half the time and saves measurements from both wavelengths into one record
  • Additional 1490 and 1625 nm wavelengths extends product use to broader applications
  • CheckActive™ feature emits an audible tone and displays an icon when a live fiber is detected, eliminating the need to set up a measurement
  • FindFiber™ Remote ID enables one individual to quickly identify cable connections or routings (especially useful at patch panels), eliminating the need for multiple technicians on opposite ends of a fiber link to match color combinations
  • Min/Max capability automates precision tracking of intermittent power fluctuations
  • Large internal memory save 1000 results which enables continuous testing and recording
  • LinkWare Cable Test Management software helps to analyze test results and create professional test reports
  • Various kit configurations for all “first line” fiber handling needs, including fiber verification, inspection, and cleaning – all housed in a professional, rugged carrying case

Product Capabilities

Today’s high-bandwidth premises networks depend on a reliable fiber optic infrastructure. Proper installation and maintenance of fiber cabling is imperative for minimizing network downtime. Whether you require basic fiber verification capabilities, advanced troubleshooting and inspection, or documented loss and power measurements, Fluke Networks’ SimpliFiber® Pro Optical Power Meter and Fiber Test Kits are the best first-line fiber instruments to meet your needs.

SimpliFiber® Pro Optical Power Meter and Fiber Test Kits include all the tools necessary to verify and troubleshoot optical fiber cabling systems, measure loss and power levels, and inspect and clean connector end-faces. Replacing the popular SimpliFiber series, these next generation optical loss test kits boast industry-leading functions such as dual-wavelength testing and automatic-wavelength detection, in addition to unique features such as CheckActive™, FindFiber™, and Min/Max. With such advanced, yet easy-to-use, capabilities that reduce test times, SimpliFiber Pro is simply the best first-line fiber test kit on the market.



Specifications
Environmental Specifications
Operating Temperature -10º C to 50º C
Storage Temperature -20º C to 50º C
Operating Humidity
  • 95% (10º C to 35º C) Non-Condensing
  • 75% (35º C to 40º C) Non-Condensing
  • Uncontrolled <10º C
EMI, RFI, EMC Standards compliant1

1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)

Optical Power Meter
Detector Type InGaAs
Calibrated Wavelengths 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm
Measurement Range
  • +10 to -52 dBm (850 nm)
  • +10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)
Power Measurement Linearity
  • ±0.2 dB (850 nm)1
  • ±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)2
Power Measurement Uncertainty3 ±0.25 dB
Display Resolution, dB or dBm 0.01 dB
Auto Dual-Wavelength Switching Yes
Power Display Units dBm, mW, μW
Auto-Wavelength Detection Yes
Data Storage 1000 records, multiple wavelengths per record
External Interface USB, 2.0 full speed
Optical Connector Removable adapter, SC adapter as default, optional adapters include LC, ST
Display update rate 1 reading per second
Reference Individually set for each wavelength
FindFiber ID detection Yes
Power Requirement 2 AA Alkaline batteries
Battery Life4 > 50 Hours (typical)
Automatic Power Off 10, 20, 30 or 60 minutes (can be disabled by user)
Low Battery Warning Yes, low battery icon blinks
Size (L x W x H) 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)
Weight 11.5 oz (325 grams)

1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm
2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm
323°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,
4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.

Multimode Optical Source
Emitter Type LED
Central Wavelength 850 nm, 1300 nm
Wavelength Accuracy
  • 850 nm: +30/- 10 nm
  • 1300 nm: +/- 20 nm
Spectral Width (FWHM)
  • 850 nm: 50 nm (typical)
  • 1300 nm: 135 nm (typical)
Minimum Output Power 850/1300 nm: ³  -20 dBm
Power Output Stability1 ±0.1 dB over 8 hours
Auto Dual-Wavelength Switching Yes. Can be enabled/disabled by user.
Optical Output Connector Fixed SC
FindFiber Code Generation Yes. Fixed at ID 1.
Modes CW, 2 kHz modulated, Auto-wavelength
Power Requirement 2 AA Alkaline batteries.
Battery Life2 40 hrs (typical)
Automatic Power Off 30 minutes (can be disabled by user)
Low Battery Warning Yes, LED blinks
Size (L x W x H) 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight 1.8 oz (278 g)

1 23° C ± 2° C, after 5 minutes warm-up time
2In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.

Singlemode Optical Source
Emitter Type FP Laser: dual 1310 nm/1550 nm
Central Wavelength 1310 nm, 1550 nm
Wavelength Accuracy
  • 1310 nm: +/- 20 nm
  • 1550 nm: +/- 30 nm
Spectral Bandwidth (RMS)
  • 1310 nm: 2 nm (maximum)
  • 1550 nm: 3 nm (maximum)
Minimum Output Power 1310/1550 nm: ³  -7 dBm (typical)
Power Output Stability1 ±0.25 dB over 8 hours
Auto Dual-Wavelength Switching Yes. Can be enabled or disabled by user.
Optical Connector Fixed SC
Launch Condition 9/125 μm fiber
FindFiber Code Generation Yes. Fixed at ID 2.
Modes CW, 2 kHz modulated, Auto-wavelength
Power Requirement 2 AA Alkaline batteries
Battery Life2 30 hrs (typical)
Automatic Power Off 30 minutes (can be enabled or disabled by user)
Low Battery Warning LED blinks.
Size (L x W x H) 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight 9.8 oz (278 grams)

1 23° C ± 2° C, after 5 minutes warm-up time
2In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.

FindFiber Source Specifications
Emitter Type Laser
Source Connector Fixed SC
FindFiber Code Generation 1 through 8. Default is 3.
Power On/Low-battery Indicator LED
Power Requirement 2 AA Alkaline batteries
Battery Life > 80 Hours (typical)
Automatic Power Off 30 minutes
Low Battery Warning LED blinks
Size (L x W x H) 7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm)
Weight 4.4 oz (125 g)
Safety Meets Class 1 CDRH


Kits

Model Number/Name Description
FTK1450 Complete Fiber Verification Kit with FT500 FiberInspector Mini – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, 1310/1550 singlemode source, VisiFault VFL, FT500 FiberInspector Mini, two (2) FindFiber Remote ID sources, and carrying case; ST and LC adapter, NFC-KIT-BOX fiber optic cleaning kit
FTK1350 Multimode Fiber Verification Kit with FT500 FiberInspector Mini – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, VisiFault VFL, FT500 FiberInspector Mini, FindFiber Remote ID source, and carrying case; ST and LC adapter
FTK1300 Multimode Fiber Verification Kit with FT120 FiberViewer – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, VisiFault VFL, FT120 FiberViewer, FindFiber Remote ID source, and carrying case; ST and LC adapter
FTK1000 Multimode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, 850/1300 multimode source, and carrying case
FTK2000 Singlemode Fiber Verification Kit – Includes SimpliFiber Pro optical power meter, 1310/1550 singlemode source, and carrying case
 