Brand : TTI - Thurlby Thandar Instruments Manufacturer Ref. : PFM3000 Order Ref. : PFM3000 Weight : 0.7 kg
Thurlby Thandar PFM3000
|
Wide frequency range and high resolution
The PFM3000 offers high sensitivity frequency measurement from 3Hz up to
3GHz in two overlapping ranges. Period measurement is also provided from 8ns to
330ms.
The PFM3000 uses a continuous reciprocal measurement technique to provide
high resolution at all frequencies with rapid update.
It offers high sensitivity across the whole frequency range. A low pass
filter can be selected to reduce high frequency signal noise at lower
frequencies.
A Large and clear display
Despite its compact dimensions, the PFM3000 incorporates a surprisingly
large 8 digit LCD.
Annunciators are provided for measurement function, measurement time,
overflow, trigger activity, low battery, and measurement units. |
|
Low power consumption and push-to-measure
Despite its wide frequency range the PFM3000 has a power
consumption that enables it to operate for many hours from a PP3
size battery.
A push-to-measure capability gives a virtually instantaneous
reading followed by an automatic power down after 15 seconds.
This provides greatly extended battery life where continuous
monitoring of the signal is not required.
Bench-top use
The PFM3000
has the performance needed for many bench-top applications, and
its built-in tilt stand sets the display at a convenient angle. |
|
|
|
MEASUREMENT FUNCTIONS
Frequency (Range A) Frequency Range: 3Hz to 125MHz Resolution: 10-7Hz to 100Hz (see Note) Frequency (Range B) Frequency Range: 80MHz to 3000MHz Resolution: 1Hz to 10kHz (see Note) Period (Range A only) Period Range: 8ns to 330ms Resolution: 10-7ns to 1us (see Note) Measurement Time Selectable as 10s, 1s or 0.1s. (Note that for the 0.1s setting the effective
measurement time is 0.3 seconds). Resolution The displayed resolution depends upon the measurement time and the input
frequency. Eight digits (or nine using an overflow indication) are displayed for a 10s
measurement time. Seven or eight digits are displayed for a 1s measurement time, and six or seven
digits for 0.1s depending upon the input frequency. Usable resolution may be further reduced by
noise, particularly at low frequencies. Accuracy Measurement accuracy is the sum of the timebase accuracy and measurement
resolution plus one count.
TIMEBASE
Crystal Oscillator Frequency:
10MHz Initial Oscillator Adjustment Error: ± 2ppm (closed-case adjustable by user) Oscillator Temperature Coefficient: Typically less than ± 0.3ppm/°C 18°C to
28°C, ±10ppm –20°C to 70°C Oscillator Ageing Rate: <± 5ppm/year
OPERATING FUNCTIONS
Press to measure With the power switch off, pressing any of the function select keys will power
the instrument up in the corresponding function. The instrument will
automatically switch off 15 seconds after the last key press. Hold Pressing the Hold key will stop further measurements being made and the current
measured value will remain in the display, with the Hold indicator on, until the
Hold key is pressed again. Noise filter The Filter key controls a low pass filter, with a cut-off frequency of about
50kHz, to ensure stable readings at low frequencies. Signal activity indicator When no input signal is detected the Trig indicator will be off, indicating that
no measurement is possible. The gate time indicator flashes until the first
measurement interval is complete.
INPUT SPECIFICATIONS
Input A Input Impedance: 1MOhm//20pF (AC coupled) Frequency Range: 3Hz to 125MHz Sensitivity: Sinewave - 15mVrms 10Hz-125MHz Input B Input Impedance: 50Ohm (AC coupled) Frequency Range: 80MHz to 3000MHz Sensitivity: Sinewave - 15mVrms 80MHz-2GHz, 50mVrms to 3GHz Maximum Input Voltage Input A and Input B: 30Vdc; 30Vrms 50Hz/60Hz reducing to 1Vrms above 1MHz Note that the inputs will not be damaged if subjected to an accidental
short-term connection to a 50/60Hz line voltage not exceeding 250V rms.
DISPLAY
No. of Digits: 8 full digits
plus overflow indicator for 8.5 digits Size of Digits: 11.5mm (0.45”) Annunciators: 15 annunciators
POWER REQUIREMENTS
Battery Type: 9V PP3 alkaline Battery Life: Typically 20 hours Low Batt. Indicator: ‘Bat’ shows in display when approximately 10% of battery
life remains
GENERAL
Operating Range: +5°C to +40°C,
20% to 80% RH Storage Range: -20°C to +60°C Environmental: Indoor use at altitudes up to 2000m Pollution Degree 2 Size: 81mm x 178mm x 30mm (W x L x D) Weight: 190gms excluding battery Electrical Safety: Complies with EN61010-1 EMC: Complies with EN61326
|