Pince wattmétrique 1200/1650 kW 1400/2000 A Wattmeter clamp 1200/1650 kW 1400/2000 A Wattmeter clamp 1200/1650 kW 1400/2000 A

French   German   Spanish    Who are we ?  | Contact us  | My Account  | Cart (0 Article)
 
CONTACT
+33 1 71 16 17 00

  Select a Domain :

  > AIR - GAS
  > CALIBRATOR
  > CASES AND HOLSTERS
  > CHEMICAL MEASUREMENTS
  > COMPONENTS & CARD TEST
  > CONNECTORS AND ADAPTERS
  > DATA ACQUISITION
  > DIMENSION-DISTANCE
  > ELECTRICAL SAFETY TEST
  > GRAPHICAL RECORDERS
  > INDIVIDUAL PROTECTION EQUIPMENTS (EPI)
  > LIGHT
  > MULTIMETER / CLAMP
  > OPTICAL / FIBER OPTICS
  > OSCILLOSCOPE
  > POWER / ENERGY / PERTURBATION
 - High power meter
 - Main disturbance monitoring
 - Power quality analyser
 - Wattmeter clamp
  > POWER SUPPLY
  > PRESSURE
  > PROBES, TEST LEADS AND CABLES
  > RF AND MICROWAVE
  > RADIOCOMMUNICATION
  > SIGNAL GENERATOR
  > SOUND AND VIBRATION
  > SPEED
  > TEACHING AIDS
  > TELECOM / DATACOM
  > TELEVISION / VIDEO TEST
  > TEMPERATURE / HUMIDITY
  > VARIOUS ACCESSORIES
  > WEATHER MEASUREMENT / METEOROLOGY
  > WEIGHING INSTRUMENTS


Help

     Tips & Tricks to use Testoon

Safety and Convention

     Electric Safety category

Catalogue

     Chauvin-Arnoux
     Fluke
     LEM Instruments
     Metrix
     Turbotronic

Company Profile

     Chauvin Arnoux
     Finest
     LEM Instruments
     Metrix
WATTMETER CLAMP 1200/1650 KW 1400/2000 A

<< Return


Wattmeter clamp 1200/1650 kW 1400/2000 A

Testoon Price : 1 288 € Exc VAT

Quantity :
 

  Add to my basket


  Get an Express Quote by email


  Tell a friend

Brand : Fluke
Manufacturer Ref. : 345

Presentation

Single and balanced triple phase power.
W, VA, VAR, kWh.
TRMS.
AC/DC current: 1400 A AC rms, 2000 A DC.
AC/DC voltage: 825V AC rms et DC .
Data recording, harmonics, inrush currents, scope function, view graphs and generate reports.

<< Similar products

  Download the data sheet

Top Characteristics Product Details

Max effective power (W) :1200 kW AC, 1650 kW DC
Nature of the network :Single-phase
Balanced three-phase
Power type (Type) :Active power (W)
Reactive power (VAR)
VA
AC/DC Max voltage (V) :825V
AC/DC Max current (V) :2000A DC, 1400A AC
Wattmeters and testers frequency range (Hz) :15Hz - 1kHz
Measurement Powermeters functions (Type) :Harmonics (THD)
Frequency
Voltage
Current
Autonomy (Hour) :12 hour
Safety Level :CAT I
CAT II
CAT III
CAT IV
Safety Overvoltage :CAT IV 600V
Additional Characteristics :USB interface
Package includes :Sacoche de transport, Logiciel Power Log, Cordons de mesure, Pinces crocodile, Sondes de test, Câble USB, Adaptateur secteur international / dispositif d'exclusion des piles, Manuel d'utilisateur en anglais imprimé, Manuels multilingues sur CD
Dimension (HxWxD) (mm) :300x98x52 mm
Net Weight (kg) :820 g
Standard Manufacturer Warranty (Year) :1 YEAR

Top Characteristics Product Details

Code : FLU345   Download the data sheet
Brand : Fluke
Manufacturer Ref. : 345
Order Ref. : FLUKE 345
Weight : 1.2 kg


Fluke 345


Power Quality Clamp Meter

This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.

With the bright color power meter display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 power analyzer is ideal for troubleshooting power quality on switching loads. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit with the power meter. The internal memory of the power analyzer enables long-term power quality logging for analysis of trends or intermittent problems.

Applications

  • Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
  • Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
  • Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
  • Load studies - Verify electrical system capacity before adding loads


  • AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
  • Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
  • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
  • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
  • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
  • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
  • Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
  • Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends
  • 3-Phase power: Built in capability for balanced loads
  • View graphs and generate reports: Use power analyzer with included Power Log software