<< Return

|
 |
Testoon Price : 2 374 € Exc VAT Quantity :


Brand : Yokogawa
Manufacturer Ref. : CA150
Presentation

Signal source: DCV, DCA, OHM, RTD, TC (10 kinds), Frequency, Pulse.
Measurement: DCV, DCA, OHM, RTD, TC (10 kinds), Frequency, Pulse.
Features: Highly accurate within 0.02% of the DC voltage range for source and measure Source and measurement can be performed simultaneously. Vertical type with large-screen display. Loop power supply function (24 VDC at a load of up to 22 mA) It is possible to measure current in the mA range while supplying power.Sink function. Sweep functions that allow 3 types of continuous outputs
<< Similar products

Download the data sheet
|
| |
 |
| Type : | Multifunction
| | Measurement/generate (type) : | mA mV V Ohm Tc RTD Frequency
| | Accuracy (%) : | 0.02%
| | Number of channels : | 2 channels: 1 for measure, 1 for generate.
| | Measures ranges : | V: 500m - 35 V
mA: 20m - 100m A
Ohm: 500 - 50k Ohm
| | Generated ranges : | V: 100m - 30 V
mA: 20mA
Ohm: 500 - 50k Ohm
| | ATEX : | Yes
| | Additional Characteristics : | -
| | Package includes : | Lead cable for generation, Lead cable for measurement, Carrying case, Terminal adapter, 6 AA battery, Instruction Manual, fuse for measurement
| | Dimension (HxWxD) (mm) : | 251x124x70 mm
| | Net Weight (kg) : | 1 kg | |
|
| |
 |
Brand : Yokogawa Manufacturer Ref. : CA150 Order Ref. : CA150 Weight : 2.5 kg
|
Handy Calibrator model CA150
|
|
|
Multi-functional and high-precision calibrator that can be used to calibrate
and test industrial process devices and various electronics equipment.
|
|
- Vertical hand-held calibrator:
Easy-to-hold vertical type is designed to make it intuitively easy
to operate, as individual functions are accessed directly by pressing
assigned keys.Using the main unit body case (model name: 93027) , you
can hang CA150 to your body or a handrail to keep it handy.
- Simultaneous signal source and measurement operations at the same time:
In conventional calibration applications, multiple devices such as
a standard generator, dial resistor and multi-meter were required. Now
with a single CA150 unit, it is possible to perform operation check at
regular inspection and maintenance of thermocouples, RTDs and
instruments, as well as maintenance and equipment diagnosis of process
devices such as transmitters, thermostats and signal converters.
- Highly accurate and multi-functional source and measurement:
High accuracy: 0.02% for the generation unit and 0.02% for the
measurement unit for DCV Range Source and measure function of DCV, DCA,
OHM, RTD, TC (10 kinds), Frequency, Pulse Source unit response time is
minimum 5msec only DC1V,10V,500ohm(excitation current 1mA)
and RTD(excitation current 1mA) of range.
- Loop power supply function:
It is possible to measure generated current signals while supplying loop power from a two-wire type transmitter (up to 22 mADC).
|