<< Return

|
 |
Testoon Price : 315 € Exc VAT
Quantity :


Brand : Fluke
Manufacturer Ref. : 117322
Presentation

Combi kit Fluke 117/322 for electrician applications.
Contain:
DMM Fluke 117.
Multimeter clamp Fluke 322.
Carrying softcase C115.
Magnetic suspension strap TPAK.
Set of test leads with hard points TL75.
3 years of warranty on Fluke 117.
2 years of warranty on Fluke 322.
1 year of warranty on accessories.
Similar products
|
| |
 |
| Data logger on PC : | No
| | Functions : | Backlight Bargraph Fuse protection
| | Direct input for current probe : | No
| | TRMS : | Yes
| | Current : | AC DC
| | Voltage : | AC DC
| | Number of points (cts) : | 6,000 counts
| | Accuracy (%) : | 0.5%
| | Voltage resolution (V) : | 0.1 mV
| | Minimum DC voltage (V) : | nc
| | Minimum AC voltage (V) : | nc
| | Maximum DC voltage (V) : | 600V DC
| | Maximum AC voltage (V) : | 600V AC
| | Minimum DC current (A) : | nc
| | Minimum AC current (A) : | nc
| | Maximum DC current (A) : | 10A DC
| | Maximum AC current (A) : | 400A AC
| | Measures (Type) : | Resistance Capacitance Frequency Continuity test Diode test Min/Max
| | Multimeter bandwidth (Hz) : | 50 kHz
| | Autonomy (Hour) : | 400 hour
| | Safety Level : | CAT I CAT II CAT III
| | Safety Overvoltage : | CAT III 600V
| | Communication interface (Type) : | na
| | Additional Characteristics : | Voltage detection without contact
Warranty:
3 years on Fluke 117.
2 years on Fluke 322.
1 year on accessories.
| | Package includes : | DMM Fluke 117, multimeter clamp Fluke 322, carrying softcase C115, magnetic suspension strap TPAK, set of test leads with hard points TL75, manual.
| | Dimension (HxWxD) (mm) : | Multimeter: 167x84x46 mm.
Clamp: 190x63x35 mm.
| | Net Weight (kg) : | 1.56 kg
| | Standard Manufacturer Warranty (Year) : | 3 YEARS | |
|
| |
 |
Brand : Fluke Serie : 110 Manufacturer Ref. : 117322 Order Ref. : FLUKE-117/322
Fluke 117
For electricians working in commercial and noncommercial premises (like hospitals and schools), the 117 is recommended. It includes extras like non-contact voltage detection to help get the job done faster and safer.
| Specifications |
| Maximum voltage between any terminal and earth ground |
|
| Surge protection |
|
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
|
| Fuse for A input |
|
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
|
| Display |
| Digital: |
6,000 counts, updates 4 per second |
|
| Bar graph |
|
33 segments, updates 32 per second |
|
| Operating Temperature |
|
| Storage Temperature |
|
| Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
| Battery Life |
|
400 hours typical, without backlight |
|
| Accuracy Specifications |
| DC millivolts |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
| DC volts |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
| Auto volts |
| Range: |
600.0 V |
| Resolution: |
0.1 V |
| Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
|
| AC millivolts1 true-rms |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
| AC volts1 true-rms |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
| Continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
|
| Ohms |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| Accuracy: |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
1.5 % + 2 |
|
| Diode Test |
| Range/Resolution: |
2.000 V / 0.001 V |
| Accuracy: |
0.9% + 2 |
|
| Capacitance |
| Range/Resolution: |
1000 nF / 1 nF |
| Range/Resolution: |
10.00 μF / 0.01 μF |
| Range/Resolution: |
100.0 μF / 0.1 μF |
| Range/Resolution: |
9999 μF / 1 μF |
| Range/Resolution: |
100 μF to 1000 μF |
| Accuracy: |
1.9% + 2 |
| Range/Resolution: |
> 1000 μF |
| Accuracy: |
5% + 20% |
|
| LoZ capacitance |
| Range: |
1 nF to 500 μF |
| Accuracy: |
10% + 2 typical |
|
| Temperature2 (Type-K thermocouple) |
| Range/Resolution: |
-40 °C to 400 °C / 0.1 °C |
| Accuracy: |
1% + 102 |
| Range/Resolution: |
-40 °F to 752 °C / 0.2 °F |
| Accuracy: |
1% + 182 |
|
| AC amps true-rms (45 Hz to 500 Hz) |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.5% + 3 |
|
20 A continuous overload for 30 seconds max |
|
| DC amps |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.0% + 3 |
|
20 A continuous overload for 30 seconds max |
|
| Hz (V or A input)2 |
| Range/Resolution: |
99.99 Hz / 0.01 Hz |
| Range/Resolution: |
999.99 Hz / 0.1 Hz |
| Range/Resolution: |
9.999 Hz / 0.001 Hz |
| Range/Resolution: |
50.00 Hz / 0.01 Hz |
| Accuracy: |
0.1% + 2 |
|
Notes:
1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is specified from 0.0V.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
| Mechanical & General Specifications |
| Size |
| Height: |
16.7 cm (6.57") |
| Length: |
8.4 cm (3.31") |
| Width: |
4.62 cm (1.82") |
|
| Weight |
|
| Warranty |
|
Fluke 322 Clamp Meter
|
Big features, small package
The Fluke 322 is designed to
verify the presence of load current, AC voltage and continuity of
circuits, switches, fuses and contacts. These small and rugged clamp
meter is ideally suited for current measurements up to 400 A in tight
cable compartments.
The Fluke 322 also offers DC voltage measurements and has a higher
resolution for loads below 40 A. |
These affordable instrument combine a compact package with a strong feature set:
- New smaller size fits easily into tight places
- Precise measurements with 1.8% basic accuracy
- Resolution up to 0.01A and 0.1 V
- Measures AC current to 400 A
- Measures AC volts to 600 V
- Measures DC volts to 600 V
- Resistance measurement to 400 Ω
- Continuity for quick checking of shorts
- Automatic low battery indicator
- Display hold function
- Two year warranty
|
| Specifications |
| Voltage DC |
| Range: |
0 - 400 V (Fluke 322 only) |
| Resolution: |
0.1 V |
| Range: |
0 - 600 V (Fluke 322 only) |
| Resolution: |
1 V |
| Accuracy: |
1% ± 5 counts |
|
| Voltage AC |
| Range: |
0 - 400 V |
| Resolution: |
0.1 V |
| Range: |
0 - 600 V |
| Resolution: |
1 V |
| Accuracy: |
1.2% ± 5 counts (50 - 400 Hz) |
| AC Response: |
Averaging |
|
| Current AC |
| Range: |
0 - 400 A |
| Resolution: |
0.1 A |
| Range: |
0 - 40 A (Fluke 322 only) |
| Resolution: |
0.01 A |
| Accuracy: |
1.8% ± 5 counts (50 - 60 Hz) |
| Accuracy: |
3.0% ± 5 counts (60 - 400 Hz) |
| AC Response: |
Averaging |
|
| Resistance |
| Range: |
0 - 400 Ω |
| Resolution: |
0.1 Ω |
| Accuracy: |
1% ± 5 counts |
|
| Continuity |
|
| Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Operating Altitude |
|
| Temperature De-rating |
|
Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC |
|
| Safety Specifications |
| Safety Rating |
|
IEC 1010-2-032, 600V CAT III |
|
| Mechanical & General Specifications |
| Size |
|
| Weight |
|
| Warranty |
|
| Battery Life |
|
100 hours typical (2 AAA carbon zinc) |
|
| Jaw Opening |
|
|
|