Enregistreur sans papier, 3 à 12 voies, 0.5 à 4 Hz (250ms à 2s) Paperless recorder, 3 to 12 channels, 0.5 to 4 Hz (250ms to 2s) Paperless recorder, 3 to 12 channels, 0.5 to 4 Hz (250ms to 2s)

French   German   Spanish    Who are we ?  | Contact us  | My Account  | Cart (0 Article)
 
CONTACT
+33 1 71 16 17 00

  Select a Domain :

  > AIR - GAS
  > CALIBRATOR
  > CASES AND HOLSTERS
  > CHEMICAL MEASUREMENTS
  > COMPONENTS & CARD TEST
  > CONNECTORS AND ADAPTERS
  > DATA ACQUISITION
  > DIMENSION-DISTANCE
  > ELECTRICAL SAFETY TEST
  > GRAPHICAL RECORDERS
 - Paper/Paperless recorders
 - XY recorders
  > INDIVIDUAL PROTECTION EQUIPMENTS (EPI)
  > LIGHT
  > MULTIMETER / CLAMP
  > OPTICAL / FIBER OPTICS
  > OSCILLOSCOPE
  > POWER / ENERGY / PERTURBATION
  > POWER SUPPLY
  > PRESSURE
  > PROBES, TEST LEADS AND CABLES
  > RF AND MICROWAVE
  > RADIOCOMMUNICATION
  > SIGNAL GENERATOR
  > SOUND AND VIBRATION
  > SPEED
  > TEACHING AIDS
  > TELECOM / DATACOM
  > TELEVISION / VIDEO TEST
  > TEMPERATURE / HUMIDITY
  > VARIOUS ACCESSORIES
  > WEATHER MEASUREMENT / METEOROLOGY
  > WEIGHING INSTRUMENTS


Company Profile

     Linseis
     Sefram
PAPERLESS RECORDER, 3 TO 12 CHANNELS, 0.5 TO 4 HZ (250MS TO 2S)

<< Return


Paperless recorder, 3 to 12 channels, 0.5 to 4 Hz (250ms to 2s)

Testoon Price : Request a quotation

  Get an Express Quote by email



Brand : Yokogawa
Manufacturer Ref. : FX100

Presentation

Paperless recorder.
Channels number: 3, 6 or 12 analog universal inputs.
Measurement interval: FX103: 250ms (4 Hz). FX106-112: 1s and 2s (0.5 and 1Hz).
Inputs: VDC (DC voltage), TC (thermocouple), RTD (resistance temperature detector), DI (digital input for event recording), DCA (DC current with external shunt resistor attached).

"Base price for one 3 channels model without option."

For the compatibility between differents options refers you to the datasheet or contact us.

<< Similar products

  Download the data sheet

Top Characteristics Product Details Options

Recorder type :Paperless recorder
Bandwidth (Hz) :4 Hz (250ms), 1/0.5 Hz (1/2 s)
Number of channels :3 channels
6 channels
12 channels
Channels type :Universal channels
Sampling rate (Sa/s) :nc
Measurements types :DC voltage
Thermocouples temperatures
PT100 temperature
Memory length (Pts) :nc
Resolution (bit) :nc
Interface (type) :RS232 + Modbus, 422A/485 + Modbus, Ethernet in option
Additional Characteristics :-
Package includes :2 mounting brackets, 3 terminal screw, 1 operation manual, 1 user's manual on CD-ROM, 1 software DAQSTANDARD on CD-ROM (Even if communication port and external memory is not selected)
Dimension (HxWxD) (mm) :144x144x234 mm
Net Weight (kg) :2.2 kg
Standard Manufacturer Warranty (Year) :1 YEAR

Top Characteristics Product Details Options

Code : YOKFX100   Download the data sheet
Brand : Yokogawa
Serie : DAQStation FX100
Manufacturer Ref. : FX100
Order Ref. : FX100
Weight : 3.2 kg


Yokogawa  FX100 series

FX100 displays real-time measurement data on TFT color LCD and saves the data in external media (3.5” FD or Flash memory card) or FTP server. It comes with a three, six or twelve-channel. As the input signal, a DC voltage, thermocouple, resistance temperature detector, or contact signal can be set to each channel.

Standard Specifications

Construction
Dimensions: 144(W) x 144(H) x 234(D) mm
Weight: FX1xx–0: 2.2 kg
            FX1xx–1: 2.5 kg
            FX1xx–4: 2.3 kg
Front panel: Water and dust-proof (based on IEC529- IP65)

Inputs

Number of inputs:
FX103: 3 channels
FX106: 6 channels
FX112: 12 channels
Measurement interval:
FX103: 250 ms
FX106, FX112: 1 s/2 s
Inputs: VDC (DC voltage), TC (thermocouple), RTD (resistance temperature detector), DI (digital input for event recording), DCA (DC current with external shunt resistor attached)

Data Saving Function

Internal memory:
Flash memory (1.2MB)
External storage medium:
Selectable from: 1) None
                         2) 3.5-inch floppy disk (2HD, 1.44 MB)
                         3) Compact flash memory card (32 to 512 MB)
Saving method: Manual or automatic selectable
Measurement data files:
Display data and event data



Top Characteristics Product Details Options

Choose an interface :
  - RS422A/485 interface (+ Modbus master) (184,08 € Exc VAT)
Choose an interface :
  - Ethernet (10 Base-T) interface (184,08 € Exc VAT)
Choose an interface :
  - RS232 interface (+ Modbus master) (184,08 € Exc VAT)
Additional functions :
  - System error/ full memory (208,62 € Exc VAT)
Additional functions :
  - Math functions + report (245,44 € Exc VAT)
Choose a number of channels :
  - 3 channels model
Choose a number of channels :
  - 6 channels model (245,44 € Exc VAT)
Choose a number of channels :
  - 12 channels model (1 104,47 € Exc VAT)
Alarm output :
  - 2 alarm relay (153,40 € Exc VAT)
Alarm output :
  - 4 alarm relay (306,80 € Exc VAT)
Alarm output :
  - 6 alarm relay (460,20 € Exc VAT)
Input type supplementary :
  - RTD inputs, 3 isolated wire (184,08 € Exc VAT)
Power supply :
  - 24 VAC/DC power supply (184,08 € Exc VAT)
Additional functions :
  - Measurement pulse (3 inputs) (429,52 € Exc VAT)
Additional functions :
  - Remote control input (8 inputs) (184,08 € Exc VAT)
Input type supplementary :
  - PT1000 inputs (184,08 € Exc VAT)
Media support :
  - Without external reader
Media support :
  - Floppy disc reader (122,72 € Exc VAT)
Media support :
  - ATA Compact Flash reader (+ 1 32MB card) (184,08 € Exc VAT)

N.B. : You will be able to select your options when you finalise your order.