<< Return

|
 |
List Price : € Exc VAT

Testoon Price : 189 € Exc VAT
Quantity :


Brand : Fluke
Manufacturer Ref. : 115
Presentation

Multimeter for field service testing.
For electrical and electronic testing in field service, industrial, etc...
* True RMS measurements
* 0.5% basic accuracy
* 6,000 counts resolution
* AutoVolt: automatic ac/dc voltage selection
* Large white LED backlight to work in poorly lit areas
* Resistance and continuity
* Min/Max/Average to record signal fluctuations
* CAT III 600 V safety rated
Download the data sheet
Similar products
|
| |
 |
| Data logger on PC : | No
| | Functions : | Large display Backlight Bargraph Fuse protection
| | Direct input for current probe : | No
| | TRMS : | Yes
| | Current : | AC DC
| | Voltage : | AC DC
| | Number of points (cts) : | 6,000 counts
| | Accuracy (%) : | 0.5%
| | Voltage resolution (V) : | 0.1 mV
| | Minimum DC voltage (V) : | nc
| | Minimum AC voltage (V) : | nc
| | Maximum DC voltage (V) : | 600V DC
| | Maximum AC voltage (V) : | 600V AC
| | Minimum DC current (A) : | nc
| | Minimum AC current (A) : | nc
| | Maximum DC current (A) : | 10A DC
| | Maximum AC current (A) : | 10A AC
| | Measures (Type) : | Resistance Capacitance Frequency Continuity test Diode test Min/Max
| | Multimeter bandwidth (Hz) : | 50 kHz
| | ATEX : | No
| | Autonomy (Hour) : | 400 hour
| | Safety Level : | CAT I CAT II CAT III
| | Safety Overvoltage : | CAT III 600V
| | Communication interface (Type) : | na
| | Additional Characteristics : | -
| | Package includes : | Holster, installed 9 V battery, TL 75 Test leads, user manual
| | Dimension (HxWxD) (mm) : | 167x84x46 mm
| | Net Weight (kg) : | 550 g
| | Standard Manufacturer Warranty (Year) : | 3 YEARS | |
|
| |
 |
Brand : Fluke Serie : 110 Manufacturer Ref. : 115 Order Ref. : Fluke-115
Model 115
An everyday multimeter for technicians, the 115 is optimized for electrical and electronic testing in field service, industrial, and applications where more than basic functionality (such as measurement of ac/dc current) simplifies working.
| Specifications |
| Maximum voltage between any terminal and earth ground |
|
| Surge protection |
|
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
|
| Display |
| Digital: |
6,000 counts, updates 4 per second |
|
| Bar graph |
|
33 segments, updates 32 per second |
|
| Operating Temperature |
|
| Storage Temperature |
|
| Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
| Battery Life |
|
400 hours typical, without backlight |
|
| Accuracy Specifications |
| DC millivolts |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
| DC volts |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
| Auto volts |
| Range: |
600.0 V |
| Resolution: |
0.1 V |
| Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz)4.0 % + 3 (500 Hz to 1 kHz) |
|
| AC millivolts1 true-rms |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
|
| AC volts1 true-rms |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
|
| Continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. |
|
| Ohms |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| Accuracy: |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
1.5 % + 2 |
|
| Diode Test |
| Range/Resolution: |
2.00 V / 0.001 V |
| Accuracy: |
0.9% + 2 |
|
| Capacitance |
| Range/Resolution: |
1000 nF / 1 nF |
| Range/Resolution: |
10.00 µF / 0.01 µF |
| Range/Resolution: |
100.0 µF / 0.1 µF |
| Range/Resolution: |
9999 µF / 1 µF |
| Range/Resolution: |
100 µF to 1000 µF |
| Accuracy: |
1.9% + 2 |
| Range/Resolution: |
> 1000 µF |
| Accuracy: |
5% + 20% |
|
| Lo-Z Capacitance |
| Range: |
1 nF to 500 µF |
| Accuracy: |
10% + 2 typical |
|
| AC amps true-rms (45 Hz to 500Hz) |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.5% + 3 |
|
20 A overload for 30-seconds max |
|
| DC amps |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.0% + 3 |
|
20 A overload for 30-seconds max |
|
| Hz (V or A input)2 |
| Range/Resolution: |
99.99 Hz / 0.01 Hz |
| Range/Resolution: |
999.9 Hz / 0.01 Hz |
| Range/Resolution: |
9.999 kHz / 0.001 kHz |
| Range/Resolution: |
50 kHz / 0.01 kHz |
| Accuracy: |
0.1% + 2 |
|
Notes:
1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is specified from 0.0V.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. 2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
| Mechanical & General Specifications |
| Size |
| Height: |
16.7 cm (6.57") |
| Length: |
8.4 cm (3.31") |
| Width: |
4.62 cm (1.82") |
|
| Weight |
|
| Warranty |
|
|