<< Return

|
 |
List Price : € Exc VAT

Testoon Price : 99 € Exc VAT
Quantity :


Brand : Standard Instruments
Manufacturer Ref. : ST-3341
Presentation

Multimeter clamp.
AC current: 40 to 1000A.
AC voltage: 400m to 600 V.
DC voltage: 400m to 600 V.
Resistance: 400 Ohm to 40 MOhm.
Capacitance: 40n to 100µ F.
Frequency: 5 to 10M Hz.
Jaw opening: 30mm.
Temperature: -58° / +1832°F (-50° / +1000°C).
Electrical safety: Cat. III 600V.
Similar products
|
| |
 |
| Jaw opening : | 30 mm
| | Current : | AC
| | Voltage : | AC DC
| | Number of points (cts) : | 4,000 counts
| | Minimum DC voltage (V) : | 400mV DC
| | Minimum AC voltage (V) : | 400mV AC
| | Maximum DC voltage (V) : | 600V DC
| | Maximum AC voltage (V) : | 600V AC
| | Minimum DC current (A) : | na
| | Minimum AC current (A) : | 40A AC
| | Maximum DC current (A) : | na
| | Maximum AC current (A) : | 1000A AC
| | Measures (Type) : | Resistance Capacitance Frequency Temperature Continuity test Diode test
| | Multimeter bandwidth (Hz) : | nc
| | Autonomy (Hour) : | nc
| | Safety Level : | CAT I CAT II CAT III
| | Safety Overvoltage : | CAT III 600V
| | Additional Characteristics : | -
| | Package includes : | Test leads, Carrying case, Temperature Probe
| | Dimension (HxWxD) (mm) : | 229x80x49 mm
| | Net Weight (kg) : | 303 g
| | Standard Manufacturer Warranty (Year) : | 1 YEAR | |
|
| |
 |
Brand : Standard Instruments Serie : ST3340 Manufacturer Ref. : ST-3341 Order Ref. : ST3341
ST-3340/3341/33431000A, AC/DC Clamp Meters |
|
|
|
|
|
3340/41/43 Series Professional AC, AC/DC Clamp Meters provide many functions for
professional AC, AC/DC measurements including resistance, capacitance and diode test, etc.
With mid-size and tear-drop shaped jaw, it is easy to use in crowded cable areas and other
tight places. |
| Specifications |
| Function |
Max Range |
Basic Accuracy |
Max. Resolution |
3340 |
3341 |
3343 |
| AC Current |
1000A |
±(2.5%+5d) |
1mA |
* |
* |
* |
| DC Current |
1000A |
±(3.0%+4d) |
10mA |
- |
- |
* |
| AC Voltage |
600V |
±(0.8%+2d) |
0.1mV |
* |
* |
* |
| DC Voltage |
600V |
±(1.0%+4d) |
0.1mV |
* |
* |
* |
| Resistance |
20MΩ |
±(1.0%+4d) |
0.1Ω |
* |
- |
- |
| 40MΩ |
±(1.0%+4d) |
0.1Ω |
- |
* |
* |
| Capacitance |
100.0nF |
±(3.0%+5d) |
0.01 nF |
- |
* |
* |
| Frequency |
100MHz |
±(1.2%+3d) |
0.01 MHz |
- |
* |
- |
| 100kHz |
±(1.2%+3d) |
0.01 kHz |
- |
- |
* |
| Duty Cycle |
99.9% |
±(1.2%+3d) |
0.1% |
- |
* |
* |
| Temperature |
1000°C/1832°F |
±(3.0%+3d) |
0.1°C/°F |
- |
* |
* |
| Size (H x W x D): 229mm x 80mm x 49mm |
| Weight: 303g |
| Accessories: Test leads, Carrying case, Temperature Probe(3341/3343) |
| Features |
|
3340 |
3341 |
3343 |
| Digital Display counts |
2000 |
4000 |
4000 |
| Electronic overload protection |
* |
* |
* |
| Continuity buzzer & Diode check |
* |
* |
* |
| Data Hold function |
* |
* |
* |
| DCA Zero function |
- |
- |
* |
| Auto Power Off |
* |
* |
* |
| Low battery indication |
* |
* |
* |
| AC/DC Current |
- |
- |
* |
|