OTDR 38/36.5 dB, 1310/1550 nm monomode, source de lumière, wattmètre intégré OTDR 38/36.5 dB, 1310/1550 nm singlemode, light source, integrated powermeter OTDR 38/36.5 dB, 1310/1550 nm singlemode, light source, integrated powermeter

French   German   Spanish    Who are we ?  | Contact us  | My Account  | Cart (0 Article)
 
CONTACT
+33 1 71 16 17 00

  Select a Domain :

  > AIR - GAS
  > CALIBRATOR
  > CASES AND HOLSTERS
  > CHEMICAL MEASUREMENTS
  > COMPONENTS & CARD TEST
  > CONNECTORS AND ADAPTERS
  > DATA ACQUISITION
  > DIMENSION-DISTANCE
  > ELECTRICAL SAFETY TEST
  > GRAPHICAL RECORDERS
  > INDIVIDUAL PROTECTION EQUIPMENTS (EPI)
  > LIGHT
  > MULTIMETER / CLAMP
  > OPTICAL / FIBER OPTICS
 - OTDR Fiber optic test set
 - Optical fiber identifier
 - Optical fiber inspection microscope
 - Optical power meters and sources
  > OSCILLOSCOPE
  > POWER / ENERGY / PERTURBATION
  > POWER SUPPLY
  > PRESSURE
  > PROBES, TEST LEADS AND CABLES
  > RF AND MICROWAVE
  > RADIOCOMMUNICATION
  > SIGNAL GENERATOR
  > SOUND AND VIBRATION
  > SPEED
  > TEACHING AIDS
  > TELECOM / DATACOM
  > TELEVISION / VIDEO TEST
  > TEMPERATURE / HUMIDITY
  > VARIOUS ACCESSORIES
  > WEATHER MEASUREMENT / METEOROLOGY
  > WEIGHING INSTRUMENTS


Help

     Tips & Tricks to use Testoon
OTDR 38/36.5 DB, 1310/1550 NM SINGLEMODE, LIGHT SOURCE, INTEGRATED POWERMETER

<< Return


OTDR 38/36.5 dB, 1310/1550 nm singlemode, light source, integrated powermeter

Testoon Price : 7 250 € Exc VAT

Quantity :
 

  Add to my basket


  Get an Express Quote by email


  Tell a friend

Brand : Anritsu
Manufacturer Ref. : MT9083A-053

Presentation

Dynamic Range: 38/36.5 dB.
Wavelength: 1310/1550 nm +30nm.
Fiber Type: Singlemode.
Pulsewidth: 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000(option) ns.
Deadzone(Fresnel): < 1 m.
Deadzone(Backscatter): < 5/5.5 m.

Integrated powermeter: -50 to -5 dBm, 1310/1550/1625/1650 nm supported.

<< Similar products

  Download the data sheet

Top Characteristics Product Details Options Associated Products

Dynamic range (dB) :38/36.5 dB
Wavelengths (nm) :1310 nm
1550 nm
Fiber type :Singlemode
Pulse width (ns) :3 ns
10 ns
20 ns
50 ns
100 ns
200 ns
500 ns
1000 ns
2000 ns
4000 ns
10000 ns
20000 ns
Reflectance accuracy (dB) :+- 2 dB
Deadzone (m) :Fresnel: <1m
Backscatter: <5/5.5m
Testing modes :Fault locate: provides end/break location, end to end loss, fiber length
Standard OTDR: user selectable automatic or manual set-up
Construction OTDR: automated, multi-wavelength testing
Light source: stabilized light source (CW, 270Hz, 1kHz, 2kHz output)
Loss test set (optional): power meter and light source
Visual fault locator (optional): visible red light for fiber identification and troubleshooting
IP test (optional): connectivity and throughput for 10/100/1000 MB
Vertical scale (dB/div) :0.05 to 6.5 dB/div
Autonomy (Hour) :8 hour
Display :6.5 inch TFT-LCD (640×480, with backlight, transparent type)
Communication interface (Type) :USB
Additional Characteristics :Pulse width 20000ns optional
Package includes :Manual, software, protector (opt10), choice of optic adapter (see option)
Dimension (HxWxD) (mm) :200x84x77 mm
Net Weight (kg) :2.9 kg
Standard Manufacturer Warranty (Year) :1 YEAR

Top Characteristics Product Details Options Associated Products

Code : ANRMT9083A-053   Download the data sheet
Brand : Anritsu
Serie : Access Master, AccessMaster, OTDR, MT9083
Manufacturer Ref. : MT9083A-053
Order Ref. : MT9083A-053
Weight : 3.9 kg


Anritsu  Access Master  MT9083A-053


All-in-One Solution for Optical Fiber Construction and Maintenance of Access, FTTx, LAN and Metro Networks

Dynamic Range: 38/36.5 dB.
Wavelength: 1310/1550 nm +30nm.
Fiber Type: Singlemode 8-10/125um.
Pulsewidth: 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000(option) ns.
Deadzone(Fresnel): < 1 m.
Deadzone(Backscatter): < 5/5.5 m.

Stabilized Light Source(through OTDR port):
                                                                        Wavelengths: Same as OTDR.
                                                                        Fiber type: Same as OTDR.
                                                                        Optical connector: Same as OTDR.
                                                                        Output Power: –5 ±1.5 dBm.
                                                                        Output Stability: +0.1dB.
Standard Integrated Power Meter(through OTDR port):
                                                                                        Measurement range: -50 to -5 dBm.
                                                                                        Fiber type: Same as OTDR.
                                                                                        Optical connector: Same as OTDR.
                                                                                        Supported wavelengths: 1310/1550/1625/1650 nm.


General specifications

Dimensions and mass:
                                        Without protector (option 010 supplied):    Size: 270(W) x 165(H) x 61(D) mm                                                                                                                                     Weight: 2.2 kg (4.8 lbs) including battery                                                            With protector (option 010 supplied):         Size: 284(W) x 200(H) x 77(D) mm                                                                                                                                     Weight: 2.9 kg (6.4 lbs) including battery.
Display: 6.5 inch TFT-LCD (640×480, with backlight, transparent type).
Interface: USB 1.1, TypeA×1(memory), Type B×1(USB mass storage).
Data storage:
                        Internal memory: 20 MB (~1000 traces).
                        External memory (USB): ~30,000 traces with 512 MB.
Power supply:
                        12 VDC, Allowable input voltage range: 10.8 – 15 VDC.
                        100 to 240 VAC, Allowable input voltage range: 90 to 264 V, 50/60 Hz.
Battery:
                Type: Lithium ion
                Operating Time: 8 hours
                Recharge Time: <5 hrs (power off).
Vertical scale: 0.05, 0.125, 0.25, 0.5, 1.25, 2.5, 5, 6.5 dB/div.
IOR setting: 1.000000 - 1.999999 (0.000001steps).
Units: km, m, kft, ft, mi.
Sampling points: Normal: 5001, High density: 20001 or 25001.
Sampling resolution: 5 cm (min).
Reflectance accuracy: Single mode: +2 dB, multimode: +4 dB.
Distance accuracy: +- 1m +- 3x measurement distance x10 +- marker resolution (excluding IOR uncertainty).
Distance range:
                            Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200 km (except 780nm: 0.5, 1, 2.5km).
                            Multimode: 0.5, 1, 2.5, 5, 10, 25, 50, 100 km.
Testing modes:
                            Fault locate: provides end/break location, end to end loss, fiber length
                            Standard OTDR: user selectable automatic or manual set-up
                            Construction OTDR: automated, multi-wavelength testing
                            Light source: stabilized light source (CW, 270Hz, 1kHz, 2kHz output)
                            Loss test set (optional): power meter and light source
                            Visual fault locator (optional): visible red light for fiber identification and troubleshooting
                            IP test (optional): connectivity and throughput for 10/100/1000 MB
Fiber event analysis:
                                    Auto or manual operation, displayed in table format
                                    User defined PASS/FAIL thresholds:
                                                - reflective and non-reflective events: 0.01 to 9.99 dB (0.01 dB steps)
                                                - reflectance: 20.0 to 60.0 dB (0.1 dB steps)
                                                - fiber end/break: 1 to 99 dB (1 dB steps)
                                    Number of detected events: up to 99
                                    Macrobend detection
OTDR trace format:Telcordia universal issue 2 (SR-4731)
Other functions:
                            Real time sweep: 0.15 second
                            Loss modes: 2 point loss, dB/km, 2 point LSA, splice loss, ORL
                            Averaging modes: timed (5 – 180 seconds)
                            Live Fiber detect : verifies presence of communication light in optical fiber( >-40dBm)
                            Connection check: Automatic check of OTDR to FUT connection quality
                            Trace overlay and comparison
EMC: EN61326:1997/A1:1998/A2 : 2003 (Class A, Annex A)
Laser safety:
                        IEC Pub 60825-1:2001 Class:1 model 051, 052, 060, 061, 062 Class:1M model 050
                        21CFR1040.10 (laser notice no. 50)

Top Characteristics Product Details Options Associated Products

Choose a connector :
  - LC connector for Access Master MT9083A OTDR
Choose a connector :
  - FC connector for Access Master MT9083A OTDR
Choose a connector :
  - ST connector for Access Master MT9083A OTDR
Choose a connector :
  - SC connector for Access Master MT9083A OTDR
Choose a connector :
  - DIN connector for Access Master MT9083A OTDR

N.B. : You will be able to select your options when you finalise your order.

Top Characteristics Product Details Options Associated Products

Anritsu
B0582A     


Soft carrying case for Access Master MT9083A OTDR
155 €
 
Anritsu
B0583A     


Hard carrying case for Access Master MT9083A OTDR
280 €
 
Anritsu
MT9083A-064     


OTDR 28/27 dB, 850/1300 nm multimode, light source, integrated powermeter
7 250 €
 
 
Contact | Who are we ? 
Terms and Conditions 




 
Réalisé par Agence Web Conseil