 | | PORTABLE DIGITAL MULTIMETER 2000 COUNTS, 0.5%, 1000V-10A DC, 750V-2A AC |  |
|
 | 
<< Return

|
 |
Testoon Price : 74 € Exc VAT Quantity :


Brand : BK Precision
Manufacturer Ref. : BK2706A
Presentation

# 2,000 counts
# 0.5% DCV accuracy
# DC voltage to 1000V
# AC voltage to 750V
# AC/DC current to 10A
# Resistance to 20M ohm
# Capacitance to 20uF
# Frequency counter
# Transistor test
# Temperature
# Continuity
# Diode test
# Protective rubber boot included
<< Similar products

Download the data sheet
|
| |
 |
| Data logger on PC : | No
| | Functions : | Fuse protection
| | Direct input for current probe : | No
| | TRMS : | No
| | Number of points (cts) : | 2,000 counts
| | Accuracy (%) : | +-(0.5% + 1d)
| | Voltage resolution (V) : | 100 uV
| | Minimum DC voltage (V) : | 200mV DC (range)
| | Minimum AC voltage (V) : | 200mV AC (range)
| | Maximum DC voltage (V) : | 1000V DC
| | Maximum AC voltage (V) : | 750V AC
| | Minimum DC current (A) : | 200uA DC (range)
| | Minimum AC current (A) : | 200uA AC (range)
| | Maximum DC current (A) : | 10A DC
| | Maximum AC current (A) : | 2A AC
| | Measures (Type) : | Resistance Capacitance Transistor Frequency Temperature Continuity test Diode test
| | Multimeter bandwidth (Hz) : | 500 Hz
| | ATEX : | No
| | Autonomy (Hour) : | 200 hour
| | Safety Level : | CAT I CAT II
| | Safety Overvoltage : | CAT II 600V / CAT I 1000V
| | Communication interface (Type) : | na
| | Additional Characteristics : | -
| | Package includes : | Battery, Test Leads, Instruction Manual, Thermocouple Probe
| | Dimension (HxWxD) (mm) : | 150x79x33 mm
| | Net Weight (kg) : | 250 g
| | Standard Manufacturer Warranty (Year) : | 1 YEAR | |
|
| |
 |
Brand : BK Precision Serie : TOOL KIT Manufacturer Ref. : BK2706A Order Ref. : BK2706A Weight : 0.65 kg
BK PRECISION BK2706A
Excellent
meters for most jobs that require flexibility, accuracy and speed.
Value packed features make these meters a must in every "Tool Kit®".
2,000 counts
0.5% DCV accuracy
DC voltage to 1000V
AC voltage to 750V
DC current to 10A
AC current to 2A
Resistance to 20M ohm
Capacitance to 20uF
Frequency counter
Transistor test
Temperature
Continuity
Diode test
Protective rubber boot included
| Specifications |
model 2706A |
| DC Volts |
|
| Ranges |
200mV, 2V, 20V,
200V, 1000V |
| Resolution |
100uV, 1mV,
10mV, 100mV, 1V |
| Accuracy |
+-(0.5% + 1
Digit) |
| Overload Protection |
200 mV Range
500V DC + AC Peak, 350V RMS Sine: All Other Ranges: 1200V DC + AC Peak,
800V RMS, Sine |
| Input Impedance |
10 M |
| AC Volts |
|
| Ranges |
200 mV, 2V,
20V, 200V, 750V |
| Resolution |
100 uV, 1 mV,
10 mV, 100 mV, 1V |
| Basic Accuracy |
+-(1.5% + 4
Digits) |
| Frequency Response |
50 to 500 Hz |
| Overload Protection |
200 mV Range:
500 VDC + AC Peak, 350V RMS, Sine: All Other Ranges: 1200 V DC + AC Peak,
800V RMS, Sine: |
| Input Impedance |
10 M |
| DC Current |
|
| Ranges |
200uA, 2mA,
20mA, 200mA, 2A, 10A, (2a: 2706A only) |
| Resolution |
0.1uA, 1uA,
10 uA, 100 uA, 1 mA, 10 mA (1 mA: 2706A only) |
| Accuracy |
+-(1% + 1 Digit):
10A Range: +-(2% + 3 Digits) |
| Burden Voltage |
10A and 200mA
range: 750mV max.; All Other Ranges: 325mV max. |
| Overload Protection |
10A Range: Unfused:
All Other Ranges: 250V Fuse |
| AC Current |
|
| Ranges |
200uA, 2mA,
20mA, 200mA, 2A, 10A (2A: 2706A only) |
| Resolution |
0.1uA, 1uA,
10uA, 100uA, 1mA, 10mA, (1 mA: 2706A only) |
| Accuracy |
+-(1.2% + 4
digits): 10A Range: +-(2% + 4 Digits) |
| Frequency Response |
50 to 500 Hz |
| Burden Voltage |
10A and 200mA
Range: 750mV max.: All Other Ranges: 325mV max. |
| Overload Protection |
10A Range: Unfused;
All Other Ranges: 250V Fuse |
| Resistance |
|
| Ranges |
200 ,
2kOhm, 20kOhm, 200kOhm, 2MOhm, 20MOhm, 200MOhm (200MOhm: 2707A only) |
| Resolution |
0.1 ,
1Ohm, 10Ohm, 100Ohm, 1 kOhm, 10 kOhm, 100 kOhm (100kOhm: 2707A only) |
| Basic Accuracy |
200 M Range (2707A only): +-(5% + 10 Dgt.); +-(0.8% + 1 Digit) |
| |
20 M Range: +-(3% + 1 Digit) |
| Overload Protection |
500 VDC + AC
Peak |
| Diode Test |
Tested at 1.6mA
and 3.2V Max. |
| Transistor Test (hFE) |
Base Current:
10 uA Vce; 2.8V; Gain Indication: 0 to 1,000 |
| Capacitance |
|
| Ranges |
2,000 pF, 20
nF, 200 nF, 2 uF, 20 uF |
| Resolution |
1 pF, 10 pF,
100 pF, 1 nF, 10 nF |
| Accuracy |
+-(3% + 10 Digits) |
| Test Frequency, Voltage |
400 Hz, 50 mV |
| Frequency |
|
| Ranges |
2 kHz, 20 kHz,
200 kHz, 2 MHz, 15 MHz |
| Resolution |
1 Hz, 10 Hz,
100 Hz, 1kHz, 10kHz |
| Accuracy |
+-(0.1% + 2
Digit) |
| Sensitivity |
1Vrms |
| Overload Protection |
500V DC + AC
Peak |
| Logic Probe (TTL) |
|
| Logic Threshold |
Does not apply |
| Minimum Pulse Width |
|
| Input Impedance |
|
| Overload Protection |
|
| Temperature |
|
| Range |
-4 0 to 14000F (-20 0 to + 7500 C) |
| Accuracy |
|
| -4 0 to + 9000F (-20 0 to 5000 C) |
+-(2% + 4 0 F)
+-(2% + 2 0 C) |
900 0 to + 14000F
(500 0 to + 7500C) |
+-(3% + 4 0 F)
+-(3% + 2 0 C) |
| Continuity Tone |
Tone Sounds
within 100 mS for Resistance Under 100V |
| General |
|
| Display |
3 1/2 digit,
high-contrast 0.7'' LCD, 1999 counts |
| Sampling |
3 times/sec.
(nominal) |
| Operating Temp: |
32 0to 104 0 F (0 0 to + 400 C), 0 to 70%
RH |
| Storage Temp |
-4 0to 140 0 F (-20 0 to 600 C), 0 to 80%
RH |
| Power Requirements |
9V NEDA 1604. |
| Battery Life |
200 hours (alkaline)
nominal 275 hours (alkaline) Nominal (2703B only) |
| Dimensions (HxWxD) |
5.9x3.1x1.3''
(150x79x33 mm) |
| One Year
Warranty |
| Accessories |
SUPPLIED: Battery,
Test Leads, Instruction Manual, Thermocouple Probe (2706A only)
OPTIONAL: TL-2A Deluxe Test
Leads, TL-3 Accessory Tip Kit (for TL-2A), PR-28A High Voltage DMM Probe
(40kVDC), TL-130A General Purpose DMM Kit
Carrying Case (not included):
LC-29B |
|
|  |
 |  |  |
|