TRMS Clamp DMM 400A.
# 4,000 counts Dual LCD display.
# True-RMS current measurements for testing Harmonic current flows.
# Measures DC Voltage to 1000V, True-RMS AC Voltage to 750V and Resistance to 40MOhm.
# Non-Contact Voltage detecting feature.
# AC/DC µA measurements.
# Frequency and Duty cycle measurements.
# Capacitance measurements.
# Diode and Continuity Beeper tests.
# Detachable Current Head-Compatible with all kinds of DC mV output adaptors.
# MAX/MIN mode (Sampling rate:100ms).
# Data Hold and Range Hold.
# K-Type thermocouple temperature measurements.
# Auto Power Off function.
# Work Light.
# Back-lit display.
# Test leads storage.
# Magnetic Mount.
# 32mm jaw size.
Similar products
|
| |
 |
| Jaw opening : | 32 mm
| | Current : | AC DC
| | Voltage : | AC DC
| | Number of points (cts) : | 4,000 counts
| | Minimum DC voltage (V) : | 1mV DC
| | Minimum AC voltage (V) : | 1mV AC
| | Maximum DC voltage (V) : | 1000V DC
| | Maximum AC voltage (V) : | 750V AC
| | Minimum DC current (A) : | 0.01uA DC
| | Minimum AC current (A) : | 0.01uA AC
| | Maximum DC current (A) : | 2mA DC
| | Maximum AC current (A) : | 400A AC
| | Measures (Type) : | Resistance Capacitance Frequency Temperature Continuity test Diode test Min/Max
| | Multimeter bandwidth (Hz) : | nc
| | Autonomy (Hour) : | nc
| | Safety Level : | CAT I CAT II CAT III
| | Safety Overvoltage : | CAT III 600V
| | Additional Characteristics : | Detachable current head to fix an adapter, hook adapter (in option): max. current 100A, double display, temperature measurement, TRMS measurement
| | Package includes : | 9V battery, test leads with FTL-500V2 alligator clips, K type thermocouple with adapter, holster
| | Dimension (HxWxD) (mm) : | 220x65x30 mm
| | Net Weight (kg) : | 490 g
| | Standard Manufacturer Warranty (Year) : | 1 YEAR | |
|
| |
 |
Brand : Finest Serie : MAXIMA Manufacturer Ref. : F129T Order Ref. : 10030121
Finest F129T
- 4000 count Dual LCD display.
- True-RMS current measurements for testing Harmonic current flows.
- Measures DC Voltage to 1000V, True-RMS AC Voltage to 750V and Registance to 40MΩ.
- Non-Contact Voltage detecting feature.
- AC/DC µA measurements.
- Frequency and Duty cycle measurements.
- Capacitance measurements.
- Diode and Continuity Beeper tests.
- Detachable Current Head-Compatible with all kinds of DC mV output adaptors.
- MAX/MIN mode (Sampling rate:100ms).
- Data Hold and Range Hold.
- K-Type thermocouple temperature measurements.
- Auto Power Off function.
- Work Light.
- Back-lit display.
- Test leads storage.
- Magnetic Mount.
- 32mm jaw size.
- IEC 1010-2-032, CATIII 600V Safety protection.
- UL-Listed & CE-mark Certificated.
| SPECIFICATIONS |
| AC Amps Measurement-jaw input (45 to 400Hz) |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 40A |
0.01A |
±2.9% + 15dgts |
400A |
| 400A |
0.1A |
±1.9% + 8dgts |
|
*45 Hz to 400 Hz True RMS(Crest factor < 3:1)
| ADP Measurement |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 400mV |
0.1mV |
±0.5% + 4dgts |
30V Max |
|
| DC micro Amps Measurement (test lead input) |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 400µA |
0.01µA |
±1.2% + 3dgts |
2000µA |
| 2000µA |
0.1µA |
±1.2% + 3dgts |
|
| AC micro Amps Measurement (test lead input, 45 to 400Hz) |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 400µA |
0.01µA |
±2.0% + 5dgts |
2000µA |
| 2000µA |
0.1µA |
±1.5% + 5dgts |
|
*45Hz to 1kHz True RMS (Crest factor < 3:1)
| DC Volts Measurement |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 400mV |
0.1mV |
±0.5% + 4dgts |
1000V |
| 4V |
1mV |
| 40V |
10mV |
| 400V |
100mV |
| 1000V |
1V |
±0.8% + 10dgts |
|
| AC Volts Measurement (45 to 400Hz) |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 4V |
1mV |
±2.0% + 5dgts |
750V |
| 40V |
10mV |
| 400V |
100mV |
| 750V |
1V |
|
*45Hz to 1kHz True RMS (Crest factor < 3:1)
| Ohms Measurement |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 400Ω |
0.1Ω |
±1.0% + 4dgts |
600V |
| 4kΩ |
1Ω |
| 40kΩ |
10Ω |
| 400kΩ |
100Ω |
| 4MΩ |
1kΩ |
| 40MΩ |
10kΩ |
±2.0% + 4dgts |
|
| Diode Test |
| Range |
Open Circuit Voltage |
Test Current(Typical) |
Overload Protection |
| 2.0V |
< 3.0V DC |
0.25mA |
600V |
|
| Capacltance Measurement |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 40nF |
0.01nF |
±3.5% + 6dgts |
600V |
| 400nF |
0.1nF |
| 4µF |
0.001µF |
| 40µF |
0.01µF |
| 400µF |
0.1µF |
| 4000µF |
1µF |
|
| Temperature Measurement |
| Range |
Resolution |
Accuracy |
Overload Protection |
-22°F to 14°F
(-30°C to -10°C) |
0.1°F
(0.1°C) |
±5.4°F
(±3.0°C) |
30V |
15°F to 752°F
(-10°C to 400°C) |
0.1°F
(0.1°C) |
±1.0% + 3.6°F
(±1.0% + 2.0°C) |
|
Sensor: K-Type Themocouple, sensor accuracy not included.
| Frequency Measurement |
| Range |
Resolution |
Accuracy |
Overload Protection |
| 9.999Hz |
0.001Hz |
±0.1% + 4dgts |
600V |
| 99.99Hz |
0.01Hz |
| 999.9Hz |
0.1Hz |
| 9.999kHz |
1Hz |
| 99.99kHz |
10Hz |
|
Minimum frequency : 0.5Hz
Sensitivity : > 1.0 Vrms
| Duty(%) Cycle Measurement |
| Range |
Accuracy |
Overload Protection |
| 0.1 to 99.9% |
±(0.2% per kHz + 0.1%) + 5count |
600V |
|
0.5Hz to 100kHz (pulse width > 2µsec )
| Continuity Measurement |
| Open circuit voltage < 2.7V |
Overload Protection |
| Threshold : Approx. < 30Ω |
600V |
|
|
|
| |
 |
Connector adapters : - -Opt No adapters - No adapter - HOOK - HOOK adapter for F127/129/129T multimeter clamps (+54,90 € Exc VAT)
N.B. : You will be able to select your options when you finalise your order.
|