<< Return

|
 |
Testoon Price : 212 € Exc VAT Quantity :


Brand : Fluke
Manufacturer Ref. : 117
Presentation

Electrician’s Multimeter with Non-Contact Voltage.
For electricians working in commercial and noncommercial premises (like hospitals and schools), the 117 is recommended. It includes extras like non-contact voltage detection to help get the job done faster and safer.
* True RMS measurements
* 0.5% basic accuracy
* 6,000 counts resolution
* VoltAlert™ technology for non-contact voltage detection
* AutoVolt automatic ac/dc voltage selection
* Low input impedance: helps prevent false readings due to ghost voltage
* Large white LED backlight to work in poorly lit areas
* True-rms for accurate measurements on non-linear loads
* Measures 10 A (20 A overload for 30-seconds)
* Resistance, continuity, frequency and capacitance
* Min/Max/Average with elapsed time to record signal fluctuations
* Compact ergonomic design for one-handed operation
* Compatible with optional magnetic hanger (ToolPak™) for hands free operation
* CAT III 600 V safety rated
<< Similar products

Download the data sheet
|
| |
 |
| Data logger on PC : | No
| | Functions : | Backlight Bargraph Fuse protection
| | Direct input for current probe : | No
| | TRMS : | Yes
| | Number of points (cts) : | 6,000 counts
| | Accuracy (%) : | 0.5%
| | Voltage resolution (V) : | 0.1 mV
| | Minimum DC voltage (V) : | nc
| | Minimum AC voltage (V) : | nc
| | Maximum DC voltage (V) : | 600V DC
| | Maximum AC voltage (V) : | 600V AC
| | Minimum DC current (A) : | nc
| | Minimum AC current (A) : | nc
| | Maximum DC current (A) : | 10A DC
| | Maximum AC current (A) : | 10A AC
| | Measures (Type) : | Resistance Capacitance Frequency Continuity test Diode test Min/Max
| | Multimeter bandwidth (Hz) : | 50 kHz
| | ATEX : | No
| | Autonomy (Hour) : | 400 hour
| | Safety Level : | CAT I CAT II CAT III
| | Safety Overvoltage : | CAT III 600V
| | Communication interface (Type) : | na
| | Additional Characteristics : | Voltage detection without contact
| | Package includes : | TL75 Test leads, holster, user manual
| | Dimension (HxWxD) (mm) : | 167x84x46 mm
| | Net Weight (kg) : | 550 g
| | Standard Manufacturer Warranty (Year) : | 3 YEARS | |
|
| |
 |
Brand : Fluke Serie : 110 Manufacturer Ref. : 117 Order Ref. : Fluke 117 Weight : 0.75 kg
Model 117
For electricians working in commercial and noncommercial premises (like hospitals and schools), the 117 is recommended. It includes extras like non-contact voltage detection to help get the job done faster and safer.
| Specifications |
| Maximum voltage between any terminal and earth ground |
|
| Surge protection |
|
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
|
| Fuse for A input |
|
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
|
| Display |
| Digital: |
6,000 counts, updates 4 per second |
|
| Bar graph |
|
33 segments, updates 32 per second |
|
| Operating Temperature |
|
| Storage Temperature |
|
| Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
| Battery Life |
|
400 hours typical, without backlight |
|
| Accuracy Specifications |
| DC millivolts |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
| DC volts |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
| Auto volts |
| Range: |
600.0 V |
| Resolution: |
0.1 V |
| Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
|
| AC millivolts1 true-rms |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
| AC volts1 true-rms |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
| Continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
|
| Ohms |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| Accuracy: |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
1.5 % + 2 |
|
| Diode Test |
| Range/Resolution: |
2.000 V / 0.001 V |
| Accuracy: |
0.9% + 2 |
|
| Capacitance |
| Range/Resolution: |
1000 nF / 1 nF |
| Range/Resolution: |
10.00 μF / 0.01 μF |
| Range/Resolution: |
100.0 μF / 0.1 μF |
| Range/Resolution: |
9999 μF / 1 μF |
| Range/Resolution: |
100 μF to 1000 μF |
| Accuracy: |
1.9% + 2 |
| Range/Resolution: |
> 1000 μF |
| Accuracy: |
5% + 20% |
|
| LoZ capacitance |
| Range: |
1 nF to 500 μF |
| Accuracy: |
10% + 2 typical |
|
| Temperature2 (Type-K thermocouple) |
| Range/Resolution: |
-40 °C to 400 °C / 0.1 °C |
| Accuracy: |
1% + 102 |
| Range/Resolution: |
-40 °F to 752 °C / 0.2 °F |
| Accuracy: |
1% + 182 |
|
| AC amps true-rms (45 Hz to 500 Hz) |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.5% + 3 |
|
20 A continuous overload for 30 seconds max |
|
| DC amps |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.0% + 3 |
|
20 A continuous overload for 30 seconds max |
|
| Hz (V or A input)2 |
| Range/Resolution: |
99.99 Hz / 0.01 Hz |
| Range/Resolution: |
999.99 Hz / 0.1 Hz |
| Range/Resolution: |
9.999 Hz / 0.001 Hz |
| Range/Resolution: |
50.00 Hz / 0.01 Hz |
| Accuracy: |
0.1% + 2 |
|
Notes:
1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is specified from 0.0V.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
| Mechanical & General Specifications |
| Size |
| Height: |
16.7 cm (6.57") |
| Length: |
8.4 cm (3.31") |
| Width: |
4.62 cm (1.82") |
|
| Weight |
|
| Warranty |
|
|