Presentation

Dual outputs DC power supply.
Output power: 280W.
Dual isolated outputs: 0-35V / 0-4A.
Independent digital voltage and current meters for each output with 3 digit resolution.
Constant voltage or constant current operation.
Compact lightweight design with low heat output.
DC output switch, automatic mode indication.
<< Similar products

Download the data sheet
|
| |
 |
| Max Power (W) : | 280 W
| | Voltage resolution (V) : | 2 mV
| | Maximum output voltage (V) : | 35 V
| | Current limit (A) : | 4 A
| | Current resolution (A) : | nc
| | Power supply type - Channel count : | Double
| | Stabilised power supply (Y/N) : | Yes
| | Safety Level : | CAT II
| | Safety Overvoltage : | nc
| | Operating mode (Type) : | Independant mode serie mode Parallel mode
| | Additional Characteristics : | -
| | Package includes : | nc
| | Dimension (HxWxD) (mm) : | 260x160x320 mm
| | Net Weight (kg) : | 4.3 kg
| | Standard Manufacturer Warranty (Year) : | 1 YEAR | |
|
| |
 |
Brand : TTI - Thurlby Thandar Instruments Serie : EX Manufacturer Ref. : EX354D Order Ref. : EX354D Weight : 5.3 kg
Thurlby Thandar EX354D
EX series - high power at low cost
The EX series provides high levels of power at surprisingly low cost.
The attractive case style is highly compact using the minimum of bench
space. The fan-less design provides silent operation *. The low weight
makes them easy to move about.
Mixed-mode regulation
The EX series combines switch-mode pre-regulation with linear
post-regulation to provide performance comparable with an all linear
design.
Excellent line and load regulation is matched by low noise and good
transient response. High power efficiency makes fan cooling unnecessary
*.
Constant voltage or constant current
The main outputs can operate in constant voltage or constant current
mode with automatic crossover and mode indication. Coarse and fine
voltage controls are provided. The current control is logarithmic
enabling low current levels to be set accurately.
Simultaneous digital metering
The EX series incorporate separate digital voltage and current meters
on each main output. The meters use bright 14mm (0.56") LED displays
and have an update rate of 4 per second providing near instantaneous
response.
Simultaneous metering of voltage and current provides accurate
information “at a glance” and avoids any possibility of
misinterpretation.
When an output switch is set to “off”, the current limit setting is
displayed enabling conditions to be set before the load is connected.
|
|
Auxiliary low-voltage output
The EX354T incorporates a third output
variable between 1.5V and 5.0V with a fixed current limit of 5A.
The set voltage can checked using the digital displays.
Single, dual or triple outputs
EX series units are available in single, dual or triple output versions.
The EX354D, for example, has two independent and isolated outputs each
with a 0 to 35V, 0 to 4A capability. The outputs can be wired in either
series or parallel to provide voltages up to 70 volts or currents up to
8 amps.
The EX354T has an additional ‘logic voltage’ output with a 5A current capability. This output
is fully variable between 1.5V and 5.0V.
Output voltages up to 150V
The EX752M is a dual output 300 watt PSU with Multi-Mode capability.
This enables it to operate as a dual power supply with two independent
and isolated outputs, or as a single power supply of double the power.
As a dual, each output provides 0 to 75V at 0 to 2A (mode A). As a
single the output can be selected as either 0 to 75V at 0 to 4A (mode
B) or 0 to 150V at 0 to 2A (mode C). In single modes, the unused half
of the unit becomes completely inoperative and its displays are blanked.
Safety and reliability
The EX series has been designed to meet the stringent requirements of
relevant IEC standards for safety and EMC. All outputs are
intrinsically short circuit proof, and are protected against external
voltages and reverse currents.
|
|
|
|
|
EX & EX-R series - combined range |
|
Single Output |
| EX355 |
35V/5A |
175
watts |
| EX1810R |
18/10A |
180
watts |
| EX2020R |
20/20A |
400
watts |
| EX4210R |
42/10A |
420
watts |
|
Dual Output |
| EX354D |
2 x 35V/4A |
280 watts |
| EX752M |
2 x
75V/2A |
300 watts |
|
Triple
Output |
| EX354T |
2 x 35V/4A + 5V/5A |
305 watts |
|
A Bus Programmable version,
the EX355P, is also available.
|
|
SPECIFICATIONS (EX Series)
MAIN OUTPUTS
|
Operating Mode
|
Constant voltage or constant current with
automatic cross-over and indication.
|
|
Voltage Setting
|
0V to >rated O/P by coarse and fine
controls.
|
|
Current Setting
|
0A to >rated O/P by single logarithmic
control.
|
|
Load regulation
|
<0.01% of max. O/P for a 90% load change.
|
|
Line regulation
|
<0.01% of max. O/P for a 10% line voltage
change.
|
|
Output impedance
|
Typically <5mW in constant voltage mode.
Typically >50kW in constant current mode.
|
|
Ripple & Noise (20MHz bandwidth)
|
Typically <2mV rms (CV mode).
|
|
Transient Response
|
<200µs to within 50mV of set
level for 90% load change.
|
|
Temp. Coefficient
|
Typically <100ppm/oC.
|
|
Output Protection
|
Outputs will withstand forward voltages
above the rated output voltage. Reverse protection by diode clamp for currents
up to 3A.
|
|
Status Indication
|
Output ON lamps. Constant current lamps.
|
|
Output Switch
|
Electronic. Preset voltage and current
displayed when output is off.
|
|
Output Terminals
|
4mm terminals on 19mm (0.75") pitch .
|
METERS (main outputs)
|
Meter Types
|
Separate 3 digit meters for voltage & current
with 14mm (0.56") LED displays. Reading rate 4/sec.
|
|
Meter Resolutions
|
100mV, 10mA.
|
|
Meter Accuracies
|
Voltage 0.3% ±1 digit. Current 0.6% ±1
digit.
|
AUXILIARY LOW VOLTAGE OUTPUT (EX354T)
|
Voltage
|
Variable <1.5V to >5V by front panel control.
|
|
Meter Voltage accuracy
|
0.3% ± 1 digit.
|
|
Current limit
|
5A minimum.
|
|
Load regulation
|
<0.5% for a 90% load change.
|
|
Line regulation
|
<0.1% for a 10% line voltage change.
|
|
Ripple & Noise (20MHz bandwidth)
|
Typically <2mVrms, <10mVpk-pk (CV mode).
|
|
Output Protection
|
Output will withstand up to 7V forward voltage. Diode clamp
reverse protection for currents up to 3A.
|
|
Output Terminals
|
4mm terminals on 19mm (0.75") pitch .
|
|
Status Indication
|
UNREG lamp.
|
POWER
|
AC Input
|
EX354D, EX354T,
EX752M: 110V to 240V ±10%, 50/60Hz.EX355, EX355P, EX1810R, EX4210R, :
220 to 240V ±10% (115V to order). Installation Category II.
|
SIZE AND WEIGHT
|
Size
|
140 x 160 x 320mm
(single); 260 x 160 x 320mm (dual/triple)
|
|
Weight
|
3.0 to 4.4kg.
|
ENVIRONMENTAL
|
Operating Range
|
+5oC to +40oC, 20% to 80% RH.
|
|
Storage Range
|
-40oC to + 70oC.
|
|
Environmental
|
Indoor use at <2000m, Pollution Degree 1.
|
|
Safety
|
Complies with EN61010-1.
|
|
EMC
|
Complies with EN61326. | |
|