<< Return

|
 |
Testoon Price : 1 170 € Exc VAT Quantity :


Brand : Gossen Metrawatt
Manufacturer Ref. : CableCop 300
Presentation

Cable detection system for electrically dead/live lines.
Voltage range: 9-300V AC/DC.
Measuring frequency: 32.768 kHz.
Typical applications: Location of cables, switches, short-circuits and earth faults, Tracing of protective conduits and coaxial cables.
<< Similar products

Download the data sheet
|
| |
 |
| Max voltage (V) : | 300 V AC/DC
| | Min voltage (V) : | 9 V AC/DC
| | Measuring frequency (Hz) : | 32.768 kHz
| | Signal (type) : | Clock cycle 0.5 s; 2 pulses of 0.0625 s duration each
| | Additional Characteristics : | -
| | Package includes : | Case with T320 transmitter, S330 signal generator, R300 receiver, two 9 V batteries, 2 measurement cables, 2 alligator clips, 2 test probes, operating instructions
| | Dimension (HxWxD) (mm) : | 310x200x85 mm
| | Net Weight (kg) : | 1.95 kg | |
|
| |
 |
| Code : GMCCableCop 300 | Download the data sheet |
Brand : Gossen Metrawatt Manufacturer Ref. : CableCop 300 Order Ref. : GTM5292000R0001 Weight : 2.35 kg
Gossen Metrawatt CableCop 300
Current-free and voltage-free, as well as current and voltage
conducting cables, can be located with the CableCop 300 cable detector
system in electrical circuits of up to 300 V.
Cables, conductors, electrical circuits, short-circuits and ground
faults can be localized, and protective conduit and coaxial cable can
be traced. The electrical circuit need not be interrupted, and
sensitive electronic components need not be switched off. Detection is
possible in walls and concrete, as well as underground.
| Voltage range |
9 ... 300 V |
| Measuring frequency |
32,768 kHz |
| Display / signal |
LED / buzzer |
| Typical applications |
Location of cables, switches, short-circuits and earth faults, Tracing
of protective conduits and coaxial cables |
| Range of applications |
Walls, ground, concrete |
| Standard equipment |
Case with T320 transmitter, S330 signal generator, R300 receiver, two 9
V batteries, 2 measurement cables, 2 alligator clips, 2 test probes,
operating instructions |
| Dimensions |
310 x 200 x 85 mm |
| Weight |
Case and contents: approx. 1.95 kg |
Receiver: Mode selection: Closed measuring circuit, live line max. 300 V Open measuring circuit, electrically dead line Range selection Amplification: x 1, x 10 or x 100 with vernier amplification setting via thumb wheel Signal generator (Measurements on live lines): Operating voltage 9 V ... 300 V AC/DC Operating frequency 32 768 kHz Signal Clock cycle 0.5 s; 2 pulses of 0.0625 s duration each Transmitter (Measuring on electrically dead lines): Operating frequency 32 768 kHz Signal Clock cycle 0.5 s; 2 pulses of 0.0625 s duration each
|