<< Return

|
 |
Testoon Price : 248 € Exc VAT Quantity :


Brand : TTI - Thurlby Thandar Instruments
Manufacturer Ref. : TG210
Presentation

Function generator.
0.02Hz to 2MHz frequency range
High waveform quality at all frequencies & levels
20mV to 20V pk-pk from 50 Ohms or 600 Ohms
Sine, square and triangle waveforms plus dc
1000:1 frequency change on each range
Variable symmetry control
External sweep input
<< Similar products

Download the data sheet
|
| |
 |
| Frequency Range (Hz) : | 2 MHz
| | Max output voltage (V) : | 20Vpp
| | Attenuation (dB) : | 20 dB
| | Wobulation (Y/N) : | Yes
| | Additional output (TTL and CMOS) : | TTL
| | Waveforms (Type) : | Sinus Square Triangle
| | Frequency meter (Y/N) : | Not include
| | Safety Level : | CAT II
| | Safety Overvoltage : | -
| | Display/resolution : | No display
| | Additional Characteristics : | Variable symmetry control
| | Package includes : | -
| | Dimension (HxWxD) (mm) : | 88x260x235 mm
| | Net Weight (kg) : | 1.9 kg
| | Standard Manufacturer Warranty (Year) : | 1 YEAR | |
|
| |
 |
Brand : TTI - Thurlby Thandar Instruments Manufacturer Ref. : TG210 Order Ref. : TG210 Weight : 2.6 kg
Thurlby Thandar TG210
Three models meeting a variety of needs
The TG210 offers all of the basic generator functions including sine,
square & triangle waveforms, variable DC offset, variable symmetry and
external sweep input.
The TG215 adds a digital display of frequency, amplitude and offset for
greater precision and convenience.
The TG230 has all the features of the TG215 plus an internal sweep
generator with linear or log sweep, variable sweep rate and a sweep output
socket. It also offers internal or external amplitude modulation.
Exceptional waveform quality
The TG200 series provides very high waveform quality under all
conditions. That means low sinewave distortion, low aberation triangle waves and
fast-edged square waves with low overshoot.
Unlike many competitive products good waveform quality is maintained throughout
the frequency range, and at low output levels.
All models have bi-directional variable symmetry at constant frequency from 1:9
to 9:1.
|
|
Digital display for precision and convenience
The TG215 and TG230 have the convenience of a digital display. Unlike
competitive products the display provides a readout not just of frequency, but
of amplitude and offset as well.
Wide range level control
The main output has a maximum emf of 20V pk-pk from a 50Ohm
or 600Ohm source. An amplitude vernier with a
range of 40dB is combined with a -20dB switched attenuator to provide levels
down to 20mV pk-pk. Variable DC offset of +/-10V is available via a centre
detent control.
An auxiliary output provides a fixed 0V to +5V level suitable for driving both
TTL and CMOS loads.
Wide sweep range
Each range can be swept by at least 1000:1 either manually or via the sweep
control input. The TG230 incorporates a versatile internal sweep generator
capable of providing linear or logarithmic frequency sweeps.
The TG230 provides further versatility by adding AM facilities. The modulation
can be external or internal (via a 400Hz internal generator) with modulation
levels fully variable between 0% and 100%.
|
|
|
|
| Frequency |
| Frequency Range |
<0.02Hz to 2MHz in 7 overlapping
decade ranges with fine adjustment by a vernier. |
| Vernier Range: |
1000:1 on each range. |
| Vernier Accuracy: |
Typically +/-5% of full scale
for TG210; see Meter Accuracy for TG215 & TG230. |
| Sweep Modes |
| Internal (TG230
only) |
| Sweep Range: |
1000:1 within each range. |
| Sweep Rate: |
Adjustable, typically 20ms to 20
secs. |
| Sweep Mode: |
Linear or logarithmic. Sweep
start and stop frequencies displayed at the press of a button. |
| External |
| Input Impedance: |
10kW |
| Input Sensitivity: |
0 to 3V for 1000:1 sweep |
| Max. Input Voltage: |
+/-10V |
| Sweep Linearity: |
Better than 1% |
| Max. Slew Rate: |
0.1V/us |
| Amplitude
Modulation (TG230 only) |
| Depth: |
Variable 0 to 100% |
| Frequency: |
400Hz (internal). DC to 100kHz
(external). |
| External Sensitivity: |
Approximately 2V peak-to-peak
for 50% modulation. |
| Meter Accuracy (TG215/230 only) |
| Frequency: |
+/- 1 digit on 2k to 2M ranges;
better than 1% of full scale on 2 to 200 ranges. |
| Amplitude: |
Typically 5% of full scale |
| DC Offset: |
Typically 2% |
| Resolution: |
0.05% maximum on all ranges (1
in 2000) |
| Update Rate: |
Varies with range; at least 2
updates per second |
| Operating Modes |
| Specifications apply
for the top decade of each frequency range and output 10V peak-to-peak
into 50W
termination. |
| Sine Distortion: |
Less than 0.5% on 200, 2k and
20k ranges; less than 1% on 2, 20 and 200k ranges; all harmonics >25dB
below fundamental on 2M range. |
| Amplitude Flatness: |
+/-0.2dB to 200kHz; +/-1dB to
2MHz. |
| Triangle Linearity: |
Better than 99% to 200kHz |
| Rise and Fall Times: |
<100ns |
| Mark - Space Ratio: |
1:1 +/- 1% to 100kHz |
| DC Range: |
+/-10V from 50W |
| Symmetry Range: |
Variable typically between 1:9
to 9:1 (on top decade of each range), frequency divided by 10. |
| Outputs |
| 50W
and 600W |
| Two
switch-selectable ranges with 40dB vernier control within each range. (No
600W
output on TG230) |
| 0dB Range: |
0.2V to 20V peak-to-peak (0.1V
to 10V into 50W). |
| -20dB Range: |
20mV to 2V peak-to-peak (10mV to
1V into 50W) |
| DC Offset Control Range: |
+/-10V from 50W.
DC offset plus signal peak limited to +/-10V (+/-5V into 50W).
DC offset plus waveform attenuated proportionally in -20dB position. |
| TTL |
| Fixed 0 to +5V
output capable of driving CMOS and 2 standard TTL loads. |
| Sweep Out |
| 6V ramp from 600W. |
| General |
| Input Voltage: |
110/120 volts AC nominal 50/60Hz
or 220/240 volts AC nominal 50/60Hz by rear panel adjustment. 25VA max. |
| Power Consumption: |
25VA max. |
| Operating Temperature Range: |
+5oC to +40oC,
20% to 80% RH. |
| Storage Temperature Range: |
-10oC to +65oC |
| Size: |
260(W) x 88(H) x 235(D)mm (10.2
x 3.4 x 9.2"), excluding handle and feet. |
| Weight: |
1.9kg (4.2lb) |
|